Changing the UV Lamp

1. Use a phillips-head screwdriver to remove the 2 screws located on

the bottom of the main body. See following figure.

2. Depress 2 clips on the back of the hood to gently release the hood

from the main body.

3. gently unplug the UV lamp from the lamp terminal and replace with

a new UV lamp.

power off before replacing the UV lamp and replace with identical type lamp.

Rating Voltage: 220VAC

8W, wave length: 253.7nm

peak Value: 780

Working Voltage: 65VAC