Step 1, Bisensor placement – Baseline Systems WaterTec S100 User Manual
Page 5

Note: When installing the biSensor connect it to the most
convenient valve. This connection is used for communication.
note
Step 1
biSensor Placement
When planning the biSensor location, take into account variables such as
distribution rate, sun exposure and soil type, or other site specific characteristics
that may affect water holding capacity or the rate at which plants use water.
The location of the biSensor will determine how frequently your sprinkler system
is allowed to water. If the biSensor is placed in an area that is generally wetter
than average it will cause your system to operate less frequently, possibly causing
dry spots. If the biSensor is placed in an area that receives less than average
water it will cause the system to operate more frequently.
Baseline biSensor placement recommendations:
• Place the biSensor near the center of a zone (should only receive water
from one zone).
• Place the biSensor in an area that receives average to slightly below average
water.
• Keep away from sidewalks and driveways to avoid water from car washing
or other factors.
The illustration to the
right identifies heavy
shadow and runoff
areas in Red and
ideal locations in
Light Green. Avoid
Red areas when
installing your
biSensor. Dark
Green areas with
some shadow can
be used as a
secondary location.
SENSOR
LOCATION
SENSOR
LOCATION
SENSOR LOCATION
SENSOR
LOCATION
N
SECONDARY
LOCATION
SECONDARY
LOCATION
5
WaterTec S100 Manual Aug06 Rev. 1