Tank changing procedures, User responsibility – Amico Automatic Cryogenic Liquid Solenoid Manifold User Manual
Page 23
www.amico.com
23
Tank Changing Procedures
WARNING: Oxygen systems must be handled with CAUTION. Spontaneous combustion may occur
if oxygen comes into contact with grease or oil. Ensure that hands, gloves, clothing and tools are
kept clean and free of oil and grease. Be careful not to introduce dust or other contaminants into
the system when changing tanks. Failure to comply with the procedure may be hazardous
WARNING: Fire Hazard. DO NOT permit smoking, or any other source of ignition in area where
the manifold is located, or near the relief valve vent outlet. Be certain that all connections are free
of dirt, grease, and oil. These substances burn with great intensity in air enriched with oxygen, or
nitrous oxide and some gas mixtures
M i c r o p r o c e s s o r D i g i t a l M a n i f o l d
P a g e : 4
USER RESPONSIBILITY
The information contained in this Installation and Maintenance Manual, pertains only to the ALERT-2
microprocessor based digital manifold. This product will perform in conformity with the descriptions
contained in this manual when assembled, operated, maintained and serviced in accordance with the
installation instructions provided.
The manifold
must be checked periodically. Parts that are broken, missing, worn, distorted or
contaminated,
must be replaced immediately. Should such repair or replacement become necessary,
please contact Amico Corporation or their distributors.
Installing CO2 and N2O manifolds outdoors. Please refer to NFPA Code: 5.1.3.3.1.8 Central
supply systems for nitrous oxide and carbon dioxide shall be prevented from reaching
temperatures lower than the recommendations of the central supply system’s manufacturer,
but shall never be lower than -7°C (20°F) or greater than 54°C (130°F).
All Manifolds should not be repaired or altered without prior written approval by Amico
Corporation or it’s distributors. Failure to comply will void all warranty on the manifold.
Statements in this manual preceded by the words
WARNING, CAUTION, DANGER and NOTE are of
special significance. Please read these sections carefully.
WARNING:
denotes steps which can prevent injury.
CAUTION:
denotes steps which can prevent damage to equipment.
DANGER:
denotes steps which can prevent electrical shock to equipment or to
prevent serious injury and/or death.
M i c r o p r o c e s s o r D i g i t a l M a n i f o l d
P a g e : 4
USER RESPONSIBILITY
The information contained in this Installation and Maintenance Manual, pertains only to the ALERT-2
microprocessor based digital manifold. This product will perform in conformity with the descriptions
contained in this manual when assembled, operated, maintained and serviced in accordance with the
installation instructions provided.
The manifold
must be checked periodically. Parts that are broken, missing, worn, distorted or
contaminated,
must be replaced immediately. Should such repair or replacement become necessary,
please contact Amico Corporation or their distributors.
Installing CO2 and N2O manifolds outdoors. Please refer to NFPA Code: 5.1.3.3.1.8 Central
supply systems for nitrous oxide and carbon dioxide shall be prevented from reaching
temperatures lower than the recommendations of the central supply system’s manufacturer,
but shall never be lower than -7°C (20°F) or greater than 54°C (130°F).
All Manifolds should not be repaired or altered without prior written approval by Amico
Corporation or it’s distributors. Failure to comply will void all warranty on the manifold.
Statements in this manual preceded by the words
WARNING, CAUTION, DANGER and NOTE are of
special significance. Please read these sections carefully.
WARNING:
denotes steps which can prevent injury.
CAUTION:
denotes steps which can prevent damage to equipment.
DANGER:
denotes steps which can prevent electrical shock to equipment or to
prevent serious injury and/or death.
1. Keep the main bank valve open throughout these procedures.
2. Close tank valves on all empty tanks.
3. Disconnect hose / pigtails from tank valve outlets using an appropriate wrench.
4. Place protective caps over the tank valves of the empty tanks and move them aside.
5. Visually inspect the tank valves for dust, grease or oil.
6. Using a clean (lint free) cloth, wipe each tank valve outlet clean. Do not use your fingers.
7. Connect the hose / pigtails to the tank valve outlets and tighten the nut with an appropriate wrench.
8. Very S-L-O-W-L-Y open the valve on the tank closest to the control cabinet. Watch the bank pressure display on
the front of the cabinet to make sure the pressure rises slowly.
9. S-L-O-W-L-Y open the remaining tank valves one at a time.