beautypg.com

Dual w-85 installation, Caution, W-85 wall control – Casablanca Fan Company PN User Manual

Page 13

background image

®

3

13

W-85

Wall Control

RED WiRE

not USED

DUAL W-85 INSTALLATION

To control the fan and lights from two locations (a three-way circuit), use two W-85

wall controls as shown in the wiring diagram in Figure #5. Before installing the

two switches into the wall, place both switches side by side, then locate the 4 dip

switches on the side of the two switches. Then make sure that the dip switches

are set to the same address on both switches as shown in Figure #4. When setting

these dip switches you are setting the channel number that is required to control

both your fan and lights from both sides of the room. If you are installing other

Inteli-Touch

®

3 fans within your home you may need to reset the dip switches on

these other fans to a different channel before installing your W-85 wall control into

the wall. Please review the section on channel changing on this instruction sheet.

DiP SWitChES

(FigURE #4)

CaUtion!

Ensure power is turned OFF at the breaker or fuse panel before starting

installation.

To control the fan and lights from two locations (a three-way circuit), use two

W-85 wall controls.

1. Remove the screws and switch plate from the existing switch box and the
screws holding the switch in the switch box.

2. Pull the existing switch from the switch box to expose the wire connections.

3. Determine which wire is connected to the common terminal from the power
source (120V AC) of the three-way switch. (The terminal will be marked
on switch).

4. Remove the wire from the common terminal of the three-way switch. Connect this

wire to the remaining black/white striped wire on the W-85 control. Secure this splice
with a wire nut.

5. Remove the two remaining wires from the three-way switch. Connect the black

wire of these wires to a black wire on the W-85 control. Secure the splice with a
wire nut. The remaining red wire is to be connected to the other red wire on the
W-85. Secure the splice with a wire nut.

6. Connect the green ground wire coming from the back of the W-85 control to the

ground wire in the switch box. Secure the splice with a wire nut.

7. Check your work by using the wiring diagrams as shown in Figure #5 on this page.

8. Install the W-85 in the wall box with the two long screws provided.

9.Install the wall plate with the two short color-matched screws provided.

10.Installation of the second W-85 control is identical. Repeat steps 1 through 9.

W-85

Wall Control

BlaCK anD WhitE

StRiPED WiRE

2 RED WiRES

2 BlaCK

WiRES

(FigURE #5)

W-84

BLACK

BLACK

BLACK

BLACK

BLACK

BLACK

BLACK

RED

GREEN

120V AC

BLACK

BLACK WITH

WHITE STRIPE

W-84

RED

RED

RED

BLACK WITH

WHITE STRIPE

GREEN

NEUTRAL

WHITE

GREEN

W-85

W-85