36in rows, 12-finger indexing, Twin row 36" 12 finger meter indexing chart – Great Plains 2525P Material Rate User Manual
Page 64

Great Plains Mfg., Inc.
62
118-231B
03/23/2010
36in Rows, 12-Finger Indexing
NOTE: This chart is for indexing finger pickup meter sprockets
only!!! Indexing sprockets will help time twin rows to drop seeds
in an alternating sequence. This chart is NOT a seed rate chart.
Twin Row 36" 12 Finger Meter Indexing Chart
Front Meter
Rear Meter
Sprocket Tooth #
Sprocket Tooth #
15400
16700
22.6
20.9
1
7
16700
18000
20.9
19.4
1
18
18000
19300
19.4
18.1
1
10
19300
20600
18.1
16.9
1
2
20600
21700
16.9
16.1
1
13
21700
23200
16.1
15.0
1
5
23200
24500
15.0
14.2
1
16
24500
25900
14.2
13.5
1
8
25900
27200
13.5
12.8
1
19
27200
28400
12.8
12.3
1
11
28400
29800
12.3
11.7
1
3
29800
31100
11.7
11.2
1
14
31100
32400
11.2
10.8
1
6
32400
33700
10.8
10.3
1
17
33700
34900
10.3
10.0
1
9
34900
36400
10.0
9.6
1
1
36400
37600
9.6
9.3
1
12
37600
38900
9.3
9.0
1
4
38900
40300
9.0
8.6
1
15
40300
41600
8.6
8.4
1
7
41600
42900
8.4
8.1
1
18
42900
44100
8.1
7.9
1
10
44100
45400
7.9
7.7
1
2
45400
46800
7.7
7.4
1
13
46800
48100
7.4
7.2
1
5
48100
49400
7.2
7.1
1
16
49400
50700
7.1
6.9
1
8
50700
52000
6.9
6.7
1
19
52000
53400
6.7
6.5
1
11
NOTE: If rear row does not appear centered between front row seeds, small adjustment
may be made to the stagger. Refer to "Adjustments to Seed Stagger on 12 Finger Meters."
NOTE: Indexing finger pickup meters can be done with the drill in planting position or with
the drill raised (all openers in their lowest position).
1. Pick the planting population which you want to plant from the chart above.
NOTE: When indexing sprockets, the top side of the meter drive chain must be tight.
2. Set the front row meter drive sprockets so the tooth stamped #1 is straight up.
3. Set the rear row meter drive sprockets to match the number from the chart above. Be sure
Population Range
Seed Spacing Range
the number is straight up.