Assemble calibration crank and coupler, Calibrate – Great Plains CALIBRATION CRANK Assembly Instructions User Manual
Page 2

152-302M
10/4/2005
Great Plains Mfg., Inc.
Calibration Crank Kit
2
Assemble Calibration Crank and 
Coupler
Refer to Figure 2
1.
Place black vinyl hand grip over calibration 
crank handle.
2.
Secure calibration crank to storage stob with 
retaining pin. 
3.
Remove washer and roll pin from jackshaft. 
Attach coupler to jackshaft and secure with 
roll pin. Discard washer. 
NOTE: Coupler should remain on jackshaft. Do 
not remove coupler even after calibration.
Calibrate
Refer to Figure 3
1.
Attach calibration crank to 706/1006NT 
gauge wheel jackshaft. Disengage lockout on 
the drive wheel. NOTE: If unit has native 
grass an extra calibration coupler is needed 
on the right hand gauge wheel. This can be 
ordered thru your Great Plains Dealer. 
2.
Rotate calibration crank to see that feed cups 
and drive are working properly and are free 
from foreign matter.
3.
To adjust seeding rate, decide which drive 
type (gearbox) setting you need from the 
seeding charts. Set the gear box. Rotate cali-
bration crank a few turns to confirm gearbox 
has been engaged.
4.
Record weight of an empty container large 
enough to hold seed metered for one acre.
5.
Turn calibration crank several times to fill seed 
cups with seed. Turn crank until seed falls to 
the ground from each cup.
6.
Rotate gauge wheel jackshaft using calibra-
tion crank about 595 rotations for the 706 and 
411 rotations for the 1006. This is equal to 
one acre.
7.
Check that the three seed cups have plenty of 
seed coming into them.
8.
Weigh metered seed. Subtract intial weight of 
container. Divide by three. Multiply by the 
number of openers on your drill to determine 
total pounds seeded per acre. If this figure is 
different than desired, set your seed rate ad-
justment handle accordingly.
NOTE: You may want to repeat the calibration pro-
cedure if your results vary greatly from the seed 
rate chart. 
23386
Figure 3
Calibrate with Calibration Crank
Figure 2
Calibration Crank Assembly
Equations for calibrating seed rate:
measured seed - empty container
3 (number of seed cups measured)
= pounds per seed cup
pounds per seed cup x number of openers = pounds per acre
23385