1.2. RELIEF VALVE INSTALLATION
1. The “P” on the relief valve must be connected to the “out” side of the pump
(see Figure 1.2 and 1.3) or directly to the “Pressure” source if using a remote
hydraulic source.
2. The “T” return or “tank” must be connected to the tank or reservoir of the Bin
Sweep.
3. If the motor turns the wrong way, first verify that the pressure and tank are
right, then try again. If motor still turns the wrong way, cross hydraulic lines
between valve and motor.
DANGER
Ensure that the return is connected to the tank
or reservoir of the Bin Sweep.
If it is not, the relief valve will not kick out and
serious injury or death can occur to the
operator.