5. Troubleshooting
Problem
Possible Cause
Remedy
Hand held trans-
mitter does not
work.
Error with coding the transmitter or receiver.
Verify that coding is correct (see
Section 6. Appendix on page 19).
Contact a Westfield customer ser-
vice representative if problem per-
sists.
Manual switch
does not work.
Incorrect or faulty wiring of the switch.
Verify that wiring to switch is cor-
rect (see Section 2.2. Hydraulic
problem persists, replace switch.
Valve only works in
one direction.
Incorrect wiring of the switch. *Incorrect wiring
may also blow the fuse in the junction box.
Verify that valve is wired correctly
(see Section 2.2. Hydraulic Con-
Manual switch and
transmitter do not
work in either
direction.
Power not reaching junction box (white light on
the manual switch does not illuminate).
• Remove and insert the 7-pin
connector from the tractor to
ensure a good connection.
• Verify the solid connection of
the power supply wire in the
junction box of the Pow-
erswing.
• Open the 7-pin connector and
verify that the black wire is
attached securely to the termi-
nal labelled “blue”, and the
white wire to the terminal
labelled “white”.
Power reaching junction box (white light on the
manual switch is illuminated).
• Open the junction box and
check the 10-amp fuse.
Replace if there is any doubt
of its condition.
• Verify that the manual switch
is wired correctly (see Section
2.2. Hydraulic Configura-
tion on page 10). If wired
incorrectly, it can override all
functions.
• Verify that the valves are
wired correctly (see Section
2.2. Hydraulic Configura-
tion on page 10).