NTP-E105 Change an Optical Port to SDH

Step 10

Click Apply.

Note

See

Chapter 7, “Manage Alarms,”

for information about the Alarm Behavior tab, including

alarm profiles and alarm suppression.

Stop. You have completed this procedure.

NTP-E105 Change an Optical Port to SDH

Step 1

Complete the

“DLP-E26 Log into CTC” task on page 16-39

at the node where you want to change the

settings. If you are already logged in, continue with Step 2.

Step 2

Double-click the OC-N card where you want to provision a port for SDH.

Step 3

Click the Provisioning > Line tabs.

Step 4

In the Type field, specify the port and choose SDH.

Step 5

Click Apply.

Table 11-4

OC-N Threshold Options (Physical)

Heading

Description

Options

Port

Port number

1 – 16 for an OC-48 card, 1 – 4 for an
OC-192 card

LBC-HIGH

Laser bias current–maximum

Default (15 min/1 day): 150 percent

LBC-LOW

Laser bias current–minimum

Default (15 min/1 day): 50 percent

OPT-HIGH

Optical power transmitted–maximum

Default (15 min/1 day): 120 percent

OPT-LOW

Optical power transmitted–minimum

Default (15 min/1 day): 80 percent

OPR-HIGH

Optical power received–maximum

Default (15 min/1 day): 200 percent

OPR-LOW

Optical power received–minimum

Default (15 min/1 day): 50 percent

Set OPR

Setting the optical power received (OPR) establishes the received power level as 100%.
If the receiver power decreases, then the OPR percentage decreases to reflect the loss
in receiver power. For example, if the receiver power decreases 3 dBm, the OPR
decreases 50%.

Purpose

This procedure provisions a port on an OC-N card for SDH.