8 specifications – Crown Audio MA-1202 User Manual
Page 24

Operation Manual
MA Series Power Amplifiers
page 24
Figure 8.2 Macro-Tech 1202 Maximum Power Matrix
8 Specifications
Maximum Power Notes:
All maximum power specifications are based on 
0.1% regulated AC mains and an ambient room 
temperature of 70°F (21°C). International units 
with multi-tap transformers are specified for the 
best-case transformer tap (normally 240 VAC, 60 
Hz). Although it is an unusual condition, your 
amplifier can function well with AC mains volt-
ages up to 10% over the specified line voltage. 
With overvoltage conditions, your amplifier may 
be capable of delivering instantaneous power 
levels up to 20% greater than the specifications 
in the matrix.
1. A single cycle sine wave is presented to the 
amplifier and monitored for nonlinear distortion. 
The average power during the burst is reported. 
Loudspeakers must be able to withstand this 
level if they are to be safely used with this ampli-
fier.
2. A 40-millisecond sine wave burst (10% duty 
cycle) is presented to the amplifier and moni-
tored for nonlinear distortion. The average power 
during the burst is reported. This power level is a 
measurement of the amplifier’s maximum tran-
sient power than can be perceived by the human 
ear.