STEP 5 - Install Fixture Chain and Ceiling Canopy
A. Adjust the Fixture Chain (GG) to your desired length by removing
the links if needed.
Pliers is required for this step.
B. With the Fixture Chain (GG) not attached to the Fixture Loop (A) and
the Canopy Chain Loop (EE), pull the supply wires through the
Fixture Chain (GG) alternating links. After the wires are through the
Fixture Chain (GG), pull the Supply Wires and the Ground Wire
through the Canopy Lock Ring (FF) and the Ceiling Canopy (II) in
order.
C. Attach one end of the Fixture Chain (GG) to the Fixture Loop (A) with
one Quick Link (HH). Lift the fixture and Fixture Chain (GG) up And
Attach the other end of the Fixture Chain (GG) onto the Canopy
Chain Loop (EE) with another Quick Link (HH). The fixture will now
hang safely. Close the chain loop at the Ceiling Canopy Loop (EE).
D. Feed the Supply Wires and Ground Wire through the Canopy Chain
Loop (EE) and Nipple (DD) into the Outlet Box. Cut the wires leaving
approximately 8” of wire extending from the Outlet Box.
E. Refer to Step 5 for wire connections.
F. Raise the Ceiling Canopy (II) and Canopy Lock Ring (FF) up the
Fixture Chain (GG) and over the Canopy Chain Loop (EE). Tighten
the Canopy Lock Ring (FF) onto the Canopy Chain Loop (EE) until
tight.
Suggested chain length for Ceiling height :
8’ ceiling : use 1 links of chain and 2 quick links
9’ ceiling : use 9 links of chain and 2 quick links
10’ ceiling : use 18 links of chain and 2 quick links
*
Figure 5
DD
A
GG
II
Supply Wires
and Ground Wire
STEP 6 - Wire Connections
A. Use standard wire connectors (not included) to make all wire
connections. (Connectors are not included with fixture.) Strip and
prepare wire ends according to instructions supplied with
connectors.
B. Connect White Supply Wire from the Outlet Box to Ribbed side Wire
from fixture.
C. Connect Black (or Red) Supply Wire from the Outlet Box to Smooth
side Wire from fixture.
D. Connect Ground Wire from the Outlet Box to Ground Wire from
fixture.
E. Twist connectors until wires are tightly joined together.
F. Wrap each connection with approved electrical tape and carefully
stuff all the connected wires into the Outlet Box.
White wire
from supply
Ribbed side wire
from fixture
Black wire from
supply (or Red)
Smooth side wire
from fixture
Ground wire
from supply
Ground wire
from fixture
Figure 6
EE
FF
HH
HH
STEP 7
Install
Candle and Bulbs
-
Wood Ball,
A. Attach one end of Long Wood Holder (C) onto the Hook on the
Fixture Body (B), the Big Wood Ball (D) onto the other end of Long
Wood Holder (C).
B. Attach the Small Wood Ball (G) onto the Short Wood Holder(F).
C. Place the Wood Plate (I) and Candle Cover (H) over the Socket.
D. This fixture uses candelabra bulb with standard screw base.
Maximum 60 watts.
E. Insert bulb and screw snugly into place.
Your fixture is now assembled and ready to use. Enjoy!
Figure 7
H
I
Bulb
Socket
Adjust the Nipple (DD) to allow the Ceiling Canopy (II) to rest
against the ceiling when held in place by the Canopy Lock Ring (FF).
D. Remove the Canopy Lock Ring (FF) and the Ceiling Canopy (II).
Tighten the Hex Nut (CC) against the Crossbar (AA) to secure in
place.
G
C
D