beautypg.com

1/ description, 2/ specifications, 3/ medium power absorber specifications – ORBIT FR Ventilated Absorbers - AEPV Series User Manual

Page 2: 4/ pressure drop specifications

background image

28

1/

Description

Ventilated absorbers are manufactured from special reticulated (open cell) foam. When used as a vent material, this
product allows air to move freely.

2/

Specifications

AEPV-4 AEPV-6 AEPV-8 AEPV-12 AEPV-18 AEPV-24 AEPV-36 AEPV-48

Height in

4 6 8 12 18 24 36 48

cm

10.2

15.2

20.3

30.5

45.7

61

91.4

121.9

Pyramids

per block

144 64 64 36 16 9 4 4

@ 125 MHz dB

28

@ 250 MHz dB

30

32

35

@ 500 MHz dB

30

35

37

40

@ 1.0 GHz dB

30

35

37

40

45

45

@ 3.0 GHz dB

30 33 37 40 45 45 50 50

@ 6.0 GHz dB

35 37 45 45 50 50 50 50

@ 10.0 GHz dB

40 40 50 50 50 50 50 50

@ 15.0 GHz dB

45 50 50 50 50 50 50 50

@ 18.0 GHz dB

50 50 50 50 50 50 50 50

Power

Watt/in

2

1

1

1

1

1

1

1

1

Watt/m

2

1550 1550 1550 1550 1550 1550 1550 1550

Weight lbs/pc.

2.5 3.5 4.5 6.5 8 11.5

16 22

kg/pc.

1.1

1.6

2

2.9

3.6

5.2

7.3

10

Absorption @ Normal Incidence

3/

Medium Power Absorber Specifications

When the material is used as a medium power absorber,
it can safely dissipate 1 W/in

2

CW with standard convec-

tion cooling. This is accomplished by the open cell cha-
racteristics of the reticulated foam, which increases the
ability of the absorber to dissipate the heat generated
by the absorption of the microwave energy. For higher
power applications of 2 - 3 W/in

2

CW, material must be

force-cooled.

4/

Pressure Drop Specifications

HVAC professionals use pressure drop calculations to
ensure adequate air flow for proper air turn-over within
a chamber.

18’

3’’

6’’

24”

24”

AEPV-18 mechanical drawing