81

>

Rotary Positioners

AL-060-1P

AL-760-1P

supplied accessories

>

CD-ROM Documentation Set:

„

User Manual (Installation, Setup, Operation & Maintenance)

technical notes

ORDERING INFORMATION

Refer to Legacy Series Polarization

Positioners – Light Duty Specifi cation
Table

„

1

All accuracy data is based on no-load conditions.

Contact ORBIT/FR for accuracy under load conditions.

„

2

AL-260-1P and larger models are equipped with

adjustable limit switches capable of approx
20° to 900° total travel. When rotary joint and slip
ring options are specifi ed, limit switches remain
but are electrically disabled.
Single-axis positioners are factory-set at:

Polarization Axis: 400° (± 200°)

„

3

Slip Ring & Rotary Joint Option Notes:

Certain slip ring options may require an extension

cap that protrudes above the turntable surface.

Positioner height may increase. Consult ORBIT/FR.

Slip ring contacts for customer use are provided

with dedicated connectors.

When rotary joint and/or slip ring options are

specifi ed, no central thru-hole is available

to the user. Option TH002 and TH003 are available

in lieu of rotary joint and/or slip ring options.

„

4

AL-260-1P and larger models are delivered standard

with synchro

„

5

AL-060-1P & AL-160-1P Models:

Contain restricted limit travel settings.

Consult

ORBIT/FR.

Rated for indoor use only.

Encoder accuracy is ± 0.03° in uni-directional

rotation and ± 0.1° in bi-directional rotation

(due to backlash).

Interface readout - incremental encoder,

(synchro not available), interfaces with AL-4160

series motion control systems only.

„

6

AL-260-1P is rated for indoor use only.