beautypg.com

ORBIT FR EMC-3 Anechoic Chamber User Manual

Page 2

background image

The advanced technology in our HyPyr-Loss

TM

hybrid mate-

rials, a unique combination of ferrite tiles & hybrid pyramid
absorbers, optimizes EMC measurement performance
between 26 MHz - 40 GHz. These hybrid absorbers require
less volumetric space than traditional absorbers (standard
carbon loaded or thin film coated pyramids).

The advantages of our unique SmartShield High Perfor-
mance shielding system are significant with performance
in excess of 100 dB for most frequencies. The construction
features of modular panels with RF connecting joints enable
an easily demountable chamber. This is a major benefit for
our customers where future relocations are necessary.

The EMC-3 is just one of a range of pre-defined EMC
test chamber designs. Others include:

EMC-MC (Mini compact)

EMC-3C (Compact 3 m test range)

EMC-5 (Compliant 5 m test range)

EMC-10 (Compliant 10 m test range)

Our vast management experience of more than 26 years
combined with specialized design tools such as Solidworks
3D, allow us to offer our customers customized, turnkey
capabilities. We are able to modify and develop our existing
designs to meet any requirement you may have.
With customer satisfaction as priority, our advanced

development and production facilities, accredited to
ISO 9001 & ISO 14001, ensure all products achieve low
maintenance and long life.

This is the ultimate 3 meter anechoic chamber ensuring fully compliant emission and immunity
testing. The high performance and compact dimensions are achieved by the use of our Smart-
Shield high performance shielding system combined with specifically developed HyPyr-Loss

TM

hybrid absorber materials for EMC test chamber applications.

PRODUCT CONFIGURATIONS

Dimensions (shielding)

8.9 m x 5.6 m x 5.8 m

Performance range

26 MHz - 40 GHz

Emission performance

CISPR-16 fully compliant 3 m site

Immunity performance

EN 61000-4-3 fully compliant 3 m site

Standard equipment

SmartShield RF shielded room, raised floor

Absorber lining: HyPyr-Loss

TM

Ferrite & Hybrid lining

QTY TYPE

1 0.9 m x 2.1 m personnel door

1 Mains filter 240 V 50/60 Hz, 32 A

4 Attenuvents (300 mm x 300 mm)

1 Consumer unit

6 Single phase sockets

4 Lights

4 n-type connectors

4 BNC type connectors

2 Fiber optic penetration waveguides

1 Penetration tube w/ cap - 5 cm

Accessories

Access doors- manual,semi & fully automatic

Turntable, Masts & Controllers

3 phase mains filters

Control data/ line filters

Test and Measurement EMC systems

Air conditioning

CCTV & Audio system

Fire detection/suppression

Chamber validation/calibration

Control room

Amplifier room

TECHNICAL DATA

Full compliance testing

IEC 61000-4-3/EN 61000-4-3

for Radiated Immunity

ISO 11452

SAE J551

CISPR 25

Full compliance testing

ANSI-C63.4

for Radiated Emissions

FCC parts 15 & 18

EN 50147-2

EN 55011/CISPR 11

EN 55016/CISPR 16

EN 55022/CISPR 22

EN 55025

VCCI V - 3/ 2004.04

Quality standards

ETSI - UKAS accredited

ISO17025; ISO9001

Environmental standard ISO 14001

2