ORBIT FR EMC-5 Anechoic Chamber User Manual
Page 2
The EMC-5 enables 4 meter antenna scans above
the ground plane and will accommodate large dimension
EUTs with turntables of 3 m diameter or more. Measurement
results are outstanding and proven in many of our customer’s
accredited facilities.
The ferrite based design is able to safely withstand
continuous field intensity of up to 200 V/m and inter-
mittent field intensity of up to 500 V/m, exceeding
most safety requirements in commercial facilities.
Specialized absorbers meeting extended power handling
about 1000V/m are also available.
Our vast management experience of more than 26 years
combined with specialized design tools such as Solidworks
3D, allow us to offer customized, turnkey capabilities. We
are able to modify and develop existing designs to meet any
specific requirements.
With customer satisfaction as priority, our advanced
development and production facilities, accredited with
ISO 9001 & ISO 14001, ensure all products achieve low
maintenance and long life.
The EMC-5 is just one of a range of pre-defined EMC
test chamber designs. Others include:
•
EMC-MC (Mini compact)
•
EMC-3C (Compact 3 m test range)
•
EMC-3 (Compliant 3 m test range)
•
EMC-10 (Compliant 10 m test range)
This 5 meter test range ensures fully compliant Emission and Immunity testing. It combines
the SmartShield high performance chamber with our specifically matched HyPyr-Loss
TM
ferrite
and hybrid absorber solution. The unique modular design of the EMC-5 chamber requires less
volumetric space than chambers with traditional absorbers.
PRODUCT CONFIGURATIONS
Dimensions (shielding)
11.5 m x 7.5 m x 5.8 m
Performance range
26 MHz - 40 GHz
Emission performance
CISPR-16 fully compliant 5 m site
Immunity performance
EN 61000.4.3 fully compliant 5 m site
Standard equipment
•
SmartShield RF shielded room
•
Absorber lining: HyPyr-Loss
TM
Ferrite
& Hybrid lining
•
Raised floor
QTY TYPE
1
3.0m X 3.0m personnel door
1
Mains filter 240 V 50/60 Hz, 32 A
8
Attenuvents (300 mm x 300 mm)
1
Consumer unit
10
Single phase sockets
4 Lights
4
n-type connectors
4
BNC type connectors
2
Fiber optic penetration waveguides
1
Penetration tube w/ cap - 5 cm
Accessories
•
Access doors- manual, semi & fully automatic
•
Turntable, masts & controllers
•
Dynamometers
•
3 phase mains filters
•
Control data/ line filters
•
Test and measurement EMC systems
•
Exhaust extraction
•
Air conditioning
•
CCTV & audio system
•
Fire detection/suppression
•
Chamber validation/calibration
•
Control room
•
Amplifier room
TECHNICAL DATA
Full compliance testing
•
IEC 61000-4-3/EN 61000-4-3
for Radiated Immunity
•
ISO 11452
•
SAE J551
•
CISPR 25
Full compliance testing
•
ANSI-C63.4
for Radiated Emissions
•
FCC parts 15 & 18
•
EN 50147-2
•
EN 5011/CISPR 11
•
EN 55016/ CISPR 16
•
EN 55022/CISPR 22
•
VCCI V - 3/ 2004.04
•
SAE J-551
•
CISPR 25
Quality standards
•
ETSI - UKAS accredited
•
ISO17025; ISO9001
•
Environmental standard ISO 14001
2