ORBIT FR EMC-10 Anechoic Chamber User Manual
Page 2
The EMC-10 chamber's small overall size results from the
use of our modular SmartShield chamber lined with our
AEPH HyPyr-Loss
TM
absorber technology. This unique de-
sign requires less volumetric space than traditional absor-
bers. It enables 4 meter antenna scans above the ground
plane and will accommodate large dimension EUTs with
turntables of 4m diameter or more.
Our vast management experience of more than 26 years
combined with specialized design tools such as Solidworks
3D, allow us to offer customized, turnkey capabilities. We
are able to modify and develop existing designs to meet any
requirement you may have.
With customer satisfaction as priority, our advanced deve-
lopment and production facilities, accredited with ISO 9001
& ISO 14001, ensure all products achieve low maintenance
and long life.
The EMC-10 is just one of a range of pre-defined EMC
test chamber designs. Others include:
•
EMC-MC (Mini compact)
•
EMC-3C (Compact 3 m test range)
•
EMC-3 (Compliant 3 m test range)
•
EMC-5 (Compliant 5 m test range)
The 10 meter test range is the Gold Standard EMC chamber design, ensuring fully compliant
Emission and Immunity testing. This chamber combines the SmartShield high performance
chamber with our specifically matched HyPyr-Loss
TM
Ferrite and hybrid absorber solution.
Measurement results are outstanding and proven in many of our customer’s accredited facilities.
PRODUCT CONFIGURATIONS
Dimensions (shielding)
21 m x 12 m x 8.5 m
Performance range
26 MHz - 40 GHz
Emission performance
CISPR-16 fully compliant 10 m site
Immunity performance
EN 61000-4-3 fully compliant 10 m site
Standard equipment
•
SmartShield RF shielded room
•
Absorber lining: HyPyr-Loss
TM
Ferrite
& Hybrid lining
•
Raised floor
QTY TYPE
1 3.0 m x 3.0 m personnel door
1 Mains filter 240 V 50/60 Hz, 32 A
8 Attenuvents (300 mm x 300 mm)
1 Consumer unit
10 Single phase sockets
4 Lights
4 n-type connectors
4 BNC type connectors
2 Fiber optic penetration waveguides
1 Penetration tube w/ cap - 5 cm
Accessories
•
Access doors- manual, semi & fully automatic
•
Turntable, Masts & Controllers
•
Vehicle Dynamometers
•
3 phase mains filters
•
Control data/ line filters
•
Test and Measurement EMC systems
•
Exhaust extraction
•
Air conditioning
•
CCTV & Audio system
•
Fire detection/suppression
•
Chamber validation/calibration
•
Control room
•
Amplifier room
TECHNICAL DATA
Full compliance testing
•
IEC 61000-4-3/EN 61000-4-3
for Radiated Immunity
•
ISO 11452
•
SAE J551
•
CISPR 25
Full compliance testing
•
ANSI-C63.4
•
FCC parts 15 & 18
•
EN 50147-2
•
EN 5011/CISPR 11
•
EN 55016/ CISPR 16
•
EN 55022/CISPR 22
•
VCCI V - 3/ 2004.04
•
SAE J-551
•
CISPR 25
Quality standards
•
ETSI - UKAS accredited
•
ISO 17025; ISO 9001
•
Environmental standard ISO 14001
2