background image

The EMC-10 chamber's small overall size results from the
use of our modular SmartShield chamber lined with our
AEPH HyPyr-Loss

TM

absorber technology. This unique de-

sign requires less volumetric space than traditional absor-
bers. It enables 4 meter antenna scans above the ground
plane and will accommodate large dimension EUTs with
turntables of 4m diameter or more.

Our vast management experience of more than 26 years
combined with specialized design tools such as Solidworks
3D, allow us to offer customized, turnkey capabilities. We
are able to modify and develop existing designs to meet any
requirement you may have.

With customer satisfaction as priority, our advanced deve-
lopment and production facilities, accredited with ISO 9001
& ISO 14001, ensure all products achieve low maintenance
and long life.

The EMC-10 is just one of a range of pre-defined EMC
test chamber designs. Others include:

EMC-MC (Mini compact)

EMC-3C (Compact 3 m test range)

EMC-3 (Compliant 3 m test range)

EMC-5 (Compliant 5 m test range)

The 10 meter test range is the Gold Standard EMC chamber design, ensuring fully compliant
Emission and Immunity testing. This chamber combines the SmartShield high performance
chamber with our specifically matched HyPyr-Loss

TM

Ferrite and hybrid absorber solution.

Measurement results are outstanding and proven in many of our customer’s accredited facilities.

PRODUCT CONFIGURATIONS

Dimensions (shielding)

21 m x 12 m x 8.5 m

Performance range

26 MHz - 40 GHz

Emission performance

CISPR-16 fully compliant 10 m site

Immunity performance

EN 61000-4-3 fully compliant 10 m site

Standard equipment

SmartShield RF shielded room

Absorber lining: HyPyr-Loss

TM

Ferrite

& Hybrid lining

Raised floor

QTY TYPE

1 3.0 m x 3.0 m personnel door

1 Mains filter 240 V 50/60 Hz, 32 A

8 Attenuvents (300 mm x 300 mm)

1 Consumer unit

10 Single phase sockets

4 Lights

4 n-type connectors

4 BNC type connectors

2 Fiber optic penetration waveguides

1 Penetration tube w/ cap - 5 cm

Accessories

Access doors- manual, semi & fully automatic

Turntable, Masts & Controllers

Vehicle Dynamometers

3 phase mains filters

Control data/ line filters

Test and Measurement EMC systems

Exhaust extraction

Air conditioning

CCTV & Audio system

Fire detection/suppression

Chamber validation/calibration

Control room

Amplifier room

TECHNICAL DATA

Full compliance testing

IEC 61000-4-3/EN 61000-4-3

for Radiated Immunity

ISO 11452

SAE J551

CISPR 25

Full compliance testing

ANSI-C63.4

FCC parts 15 & 18

EN 50147-2

EN 5011/CISPR 11

EN 55016/ CISPR 16

EN 55022/CISPR 22

VCCI V - 3/ 2004.04

SAE J-551

CISPR 25

Quality standards

ETSI - UKAS accredited

ISO 17025; ISO 9001

Environmental standard ISO 14001