Positioning, Electrical characteristics – ORBIT FR Professional GALILEO, GPS Terminal Antennas User Manual
Page 2
87
>
Positioning
Electrical characteristics
Part number
ANTE 005-A
Operational frequency bands
B1 Galileo/GPS: 1575.42 ± 20.46 MHz
(GPS L1 C/A, GPS L1 P(Y), GAL L1F, SBAS L1)
B2 Galileo/GPS/GLONASS: 1227.60 ± 61.38 MHz
(GPS L5, GPS L2C, GPS L2 P(Y), GAL E5a,
GAL E5b, SBAS L5, GLO L2 C/A, GLO L2 P, GAL E6C)
Option:
reduced B1 and/or B2 bands
Polarization*
Right hand circularly polarized
Coverage*
Maximized within a conical coverage up to 85 degrees from zenith
Gain antenna (without LNA)*
> +5 dBi at zenith
> 0 dBi from 25 deg to 90 deg elevation
> -6 dBi from 5 to 25 degrees elevation
< -6 dBi below 5 degree elevation
Gain*
LNA gain > 25 dB
Gain antenna with LNA > 30 dB
Axial Ratio*
< 7 dB between 5 and 10 degrees elevation
< 5 dB between 10 and 30 degrees elevation
< 3 dB between 30 and 60 degrees elevation
< 2 dB above 60 degrees elevation
Phase center knowledge accuracy*
Within 5 mm radius
Phase center stability
< 0.5 mm radius for E5 and E6 Galileo, L5 and L2 GPS
< 1.0 mm radius for L1 Galileo, L1 GPS
Group delay variation
< 6 ns for E5 and E6 Galileo, L5 and L2 GPS at fi xed temperature
< 14 ns for L1 Galileo, L1 GPS at fi xed temperature
Group delay stability*
< ± 300 ps at a given frequency point over temperature
Signal to noise density ratio*
C/No
≥ 35 dBHz at E5, E6 or L1 Galileo and L5, L2, L1 GPS reference conditions
LNA 1dB compression point*
≥ 18 dBm
LNA Output 3
rd
order intercept*
≥ 20 dBm
LNA Burn-out protection (CW)*
Antenna system able to withstand with no damage an in-band +20 dBm CW signal
LNA Burn-out protection (In-band Pulse)*
Antenna system able to withstand with no damage an in-band
pulsed interference with the following characteristics:
• Pulse peak power: +30 dBm
• Pulse max width: 1ms (max duty cycle of 10%)
(*) Applicable to each of the Galileo and GPS frequency bands (Galileo E5, Galileo E6, Galileo L1, GPS L5, GPS L2 and GPS L1)
ENVIRONMENTAL TESTING:
• Thermal cycling test performed according to the norm IEC 60068-2-14.
• Sine vibration test performed according to the norm IEC 60068-2-6.
• Random vibration test performed according to the norm IEC 60068-2-64.
• Free fall test performed according to the norm IEC 60068-2-32