4
5.4
side Installation -
Cata-dyne™ standard mounting bracket:
use a 5/32” allen key
(i) remove the 1.5” hex head cap screws
from the back of the stratafan™ and
flip the rear mounted clamp bracket.
install the 2.5” long, 5/32” socket
cap screws using a 5/32” allen key.
This will leave a 1/2” (12.7 mm)
gap between the clamp and the
stratafan™ unit.
(ii) align the hole in the stratafan™ clamp
bracket with any available hole in
the cata-dyne™ standard mounting
bracket. Ensure that the heat collection
plate is fully exposed to the front face of
the heater.
(iii) Hold the stratafan™ in the desired
mounting position and install the
5/16” x 1” bolt through the stratafan™
clamp and the mounting bracket.
secure the stratafan™ to the heater by
tightening the nut and the lock washer to
the bolt.
(iv) check to see that there is no space
between the front clamp and the bezel.
if there is space, remove the stratafan™
and tighten the hex head socket
cap screws, drawing the rear clamp
closer to the fan body.
(v) Tighten the front mounted set screws
through the holes in the front heat
collection plate. This should firmly secure
the stratafan™ to the heater itself.
separate Installation and Operation Instructions are available for industrial heating applications.
5/16” hex