CCI Thermal Technologies AC-R - Gas Pressure Regulator User Manual
Introduction, P.e.d. category, Product description
STANDARD LOW PRESSURE REGULATOR
AC-R-P250
INSTRUCTION MANUAL
The AC-R-P250 can be used in all industrial indoor
locations where a pressure reduction is required.
CCI Thermal Technologies Inc. equipment
must be installed, operated, and maintained in
accordance with, federal, state, provincial and
local codes. The installation must comply with
CSA, regulators and NFPA No. 54 &
No. 58 standards.
Only personnel trained in the proper
procedures, codes, standards and regulations
of the liquid propane gas and natural gas
industry should install and service this
equipment. Failure to follow these instructions
or to properly install and maintain this
equipment can result in an explosion and/or
fire causing property damage, personal injury
or death.
The regulator’s vent (or vent assembly or vent
tube),
must remain unobstructed at all times.
Close the supply valve immediately if gas can be
smelled, appliance pilot lights fail to stay on or
appear higher than usual, or any other abnormal
situation occurs.
INTRODUCTION
Scope of the Manual
This instruction manual covers installation for the
following low-pressure regulator: AC-R-P250.
E-mail: [email protected]
www.ccithermal.com
11815.Rev.3.01
Date of Issue: January 2013
alteration, excessive vibration, service or maintenance
can cause property damage, injury or death. Read the
installation, operating and maintenance instructions
thoroughly before installation or servicing this equipment.
WARNING:
Improper installation, adjustment,
Head Office & Factory:
5918 Roper Road, Edmonton, Alberta, Canada T6B 3E1
Telephone: (780) 466-3178 Fax: (780) 468-5904
Toll Free: 1-800-661-8529
P.E.D. CATEGORY
This product may be used as a safety accessory
with pressure equipment in the following Pressure
Equipment Directive (P.E.D.) 97/23/EC categories. It
may also be used outside of the Pressure Equipment
Directive using sound engineering practice (SEP)
per below.
PRODUCT SIZE
CATEGORIES
FLUID TYPE
DN 6 (1/4”)
SEP
1
PRODUCT DESCRIPTION
The AC-R-P250 is used to regulate the pressure
from 250 psig (1.7 MPa) to an adjustable low pressure
(inches of water column).
SPECIFICATIONS
Maximum Allowable Inlet Pressure
250 psig (1.7 MPa)
Outlet Pressure Standard Setpoints Available
11” w.c.
4.5” w.c.
Body Sizes and End Connection Style
Inlet: 1/4” NPT
Outlet: 3/8” NPT
Temperature Capabilities
-40°F to 130°F (-40°C to 55°C)
Vent Size
1/8” NPT
WARNING
Inlet
Closing Cap
Vent
Outlet
Figure 1
Figure 2
C US
®