4 remote exhaust hook-up – Trebor 620R Magnum User Manual
Page 7
MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL
PAGE 7
1.4 REMOTE EXHAUST HOOK-UP
Some installations may benefit from remotely exhausting air from the pump to
eliminate unwanted air turbulence or to prevent potentially damaging chemical
vapors from entering the pump air cavities.
Remove existing Muffler Assembly from the back of pump head.
Install Exhaust Plug in Exhaust Port.
Install
the appropriately sized (3/8” OD) fitting and tubing (not provided) to
remote exhaust. A remote muffler assembly may be installed at the point of
exhaust if required for condition needing the check muffler (see Section
1.3.b).
NOTE:
To maintain optimum pump performance use 3/8” (8mm) tubing minimum
at a length of 10 ft. (3 meters) maximum.
Figure 1-3: Remote Exhaust