beautypg.com

5 parts list, 6 clean-up, 7 disassembly – Trebor 610NM Magnum User Manual

Page 14

background image

PAGE 14

MAGNUM 610NM PUMP OPERATION / MAINTENANCE MANUAL

4.5 PARTS LIST

ILL
NO

PART NO

QTY

DESCRIPTION

PM

YEAR #

MATERIAL

1

C0104

1

Body

PTFE

2

98002334

4

O-Ring

2

PTFE

3

98001415

4

Check Ball

2

PTFE

4

1610B0007

2

Suction Sleeve

PTFE

5

1610B0008

2

Discharge Sleeve

PTFE

6

AM084

2

Check Cap Seal

2

PTFE

7

C0133

2

Check Bore Cap

PTFE

8

98001976

2

Shaft Seal

2

PTFE

9

1610B0022

1

Shaft

2

PFA

10

C0095

2

Push Plate

PTFE

11

C0100

2

Diaphragm Set

1 & 2

PFA

12

98001422

2

Main Seal

1 & 2

Viton

13

1610B0010

6

Tie Bolt Assembly

SS416, PFA

14

C0059

1

Slave Head

PP

15

98001109

12

Tie Bolt Cap

2

PU

16

98002643

2

O-Ring

Viton

17

C0055

2

Pilot Spool

PEEK

18

C0063

2

Pilot Cap

PP

19

98002650

2

O-Ring

2

Viton

20

98002620

1

Label Cap

PE

21

98002331

2

O-Ring

2

Viton

22

1610A0013

1

Pilot Transfer Tube

PFA

23

98002332

2

O-Ring

Viton

24

1110A0022

2

Main Transfer Tube

PFA

25

AM022

1

Mounting Base

PP

26

98003207

4

Mounting Screw

PP

27

98003071

1

Screw

PP

28

AM023

1

Locking Lever

PP

29

C0102

1

Base

PP

30

C0124

1

Shuttle/Detent Cap

PP

31

C0071

1

NM Sleeve Assembly

Ceramic,

Viton

32

C0128

1

Spool/Detent Assembly

Ceramic,

PEEK, NYL

32a

J0064

1

Shuttle Spool

Ceramic

32b

C0126

1

Spool Head

PEEK

32c

C0127

1

Detent Body

6 mo., 1 & 2

PEEK

32d

C0125

2

Detent Leg

NYL

33

C0135

1

Check Muffler Assembly

2

PP, NPRN

34

98002338

6

Nut, Flanged

SS18-8

35

C0098

1

Master Head

PP

4.6 CLEAN-UP

To help remove potentially dangerous chemicals, the pump should be flushed
with DI water or disassembled and thoroughly cleaned.

4.7 DISASSEMBLY

During the life of the pump it will be necessary to perform certain preventative
maintenance procedures to ensure its continued high performance. This section
and the next (4.8

Assembly) are provided for the user’s convenience in

disassembly and re-assembly procedures.

Thoroughly clean / flush the pump using DI water (Refer to Section 4.6 Clean

Up).