Performance
TerraLUX D
R
V
Out of fixture
Light engine only – no diffuser
Color Temperature
3000K, 3500K and 4000K
CRI: Min [typical]
80 [83]
Light Output [lumens] @ 120V
118 (18W CFL eq.)
858
1300
126 (26W CFL eq.)
950
1440
132 (32W CFL eq.)
1150
1742
142 (42W CFL eq.)
1285
1947
Power [Watts]
118 (18W CFL eq.)
13
13
126 (26W CFL eq.)
14.5
14.5
132 (32W CFL eq.)
17.5
17.5
142 (42W CFL eq.)
19.5
19.5
Efficacy [lm/W] @ 120V
66
100
Notes:
•
Typical Performance @ 25°C. See Relative Light Output vs Temperature and LEDSense® graphs, page 3, for temperature & Power de-rating.
•
All specifications subject to tolerance of ± 10%
•
Estimates, will be updated with measurements by third party per IESNA-LM79-08
LEDSense
®
Operation, Thermal De-rating and Lumen Maintenance
The D
R
V employs TerraLUX’s patented LEDSense
®
Thermal Management Technology to
automatically provide maximum light output in various fixtures and operating conditions while
assuring long-term lumen maintenance. LED-Sense
®
regularly measures the operating temperature
and ensures compliance with a pre-programmed temperature and drive-current profile. This profile
is based on the LED manufacturer’s LM-80 data report and minimum L70@60,000 hour lumen
maintenance curves. LEDSense
®
is always active, and will compensate for variation in thermal
conditions due to heatsinking, ambient air, Engine positioning, or any other variable that affects the
operating temperature. The Thermal De-rating curve below identifies the relative light output that
can be expected under various thermal conditions. The LEDSense
®
Power Curve identifies the
reduction in input power over temperature.