Performance, Ledsense, Operation, thermal de-rating and lumen maintenance – TERRALUX DR8 User Manual
Page 2

2
TerraLUX D
R
8 Product Specification – Subject to change without notice
WWW.TERRALUX.COM
10/01/2014
Performance
Notes:
•
Typical Performance @ 25°C. See Relative Light Output vs Temperature and LEDSense® graphs, page 3, for temperature &
Power de-rating.
•
All specifications subject to tolerance of ± 10%
•
Estimates, will be updated with measurements by third party per IESNA-LM79-08
TerraLUX D
R
8
Out of fixture
Light engine only – no diffuser
Color Temperature
3000, 3500 and 4000K
CRI: Min [typical]
80 [83]
Light Output [lumens] @ 120V
226 (2x26W CFL Eq.)
1900
2900
232 (2x32W CFL Eq.)
2100
3200
242 (2x42W CFL Eq.)
2600
3900
Power [Watts]
226 (2x26W CFL Eq.)
26
232 (2x32W CFL Eq.)
28
242 (2x42W CFL Eq.)
34
Efficacy [lm/W] @ 120V
75
110
LEDSense
®
Operation, Thermal De-rating and Lumen Maintenance
The D
R
8 employs TERRALUX’s patented LEDSense
®
Thermal Management Technology to
automatically provide maximum light output in various fixtures and operating conditions while
assuring long-term lumen maintenance. LED-Sense
®
regularly measures the operating temperature
and ensures compliance with a pre-programmed temperature and drive-current profile. This profile
is based on the LED manufacturer’s LM-80 data report and minimum L70@60,000 hour lumen
maintenance curves. LEDSense
®
is always active, and will compensate for variation in thermal
conditions due to heatsinking, ambient air, Engine positioning, or any other variable that affects the
operating temperature. The Thermal De-rating curve below identifies the relative light output that
can be expected under various thermal conditions. The LEDSense
®
Power Curve identifies the
reduction in input power over temperature.