Tests and certifications – TERRALUX SR8 Spec Sheet User Manual
Page 4

4
TERRALUX S
R
8 Product Specification – Subject to change without notice
WWW.TERRALUX.COM
8/07/2014
Tests and Certifications
Product Safety Certifications
• UL Standards 8750 (Recognized Component), 1598C (LED Retrofit Kit)
• CSA Standard C22.2 No. 250.0-08
Radio Frequency Emissions
FCC Part 15, Unintentional Radiators Class B.
Reduction of Hazardous Substances
(RoHS)
European Council Directive 2002/95/EC
Input Voltage Range/Frequency Range
•
108
Vac—132
Vac
/
47Hz—63Hz
•
250
Vac—300
Vac
/
47Hz—63Hz
Power Factor
•
0.988
@
120
Vac
•
0.945
@
277
Vac
Total Harmonic Distortion (THD)
•
13.7%
@
120
Vac
•
18.3%
@
277
Vac
Electrical Fast Transients
IEC/EN 61000-‐4-‐5 ±1 kV
Surge
IEC/EN 61000-‐4-‐5 ±500V Differential mode / ±1 kV Common mode
Voltage Harmonics
IEC/EN 61000-‐3-‐2
Voltage Dips and Interrupts
Mains
dips
of
30%
for
500ms,
95%
for
10ms,
and
interruptions
of
95%
for
5s
Electrostatic Discharge
± 6 kV Contact mode, ± 10 kV Air Gap
Shock and Vibration
Operating – Non Operating
Impact
1 m product drop, 1.3 m steel ball impact
Operating Temperature
-‐40°C to +55°C, 0 to 95% R.H. / 153 hr
Storage Temperature
-‐40°C to +85°C / 60 hr. followed by 20°C to 85°C, 5 to 95% R.H. / 80 hr
Lumen Maintenance
L70
=60,000hr
per
IES
TM-‐21-‐11
(Based
on
LED
Manufacturer’s
measurement
per
IES
LM-‐80-‐08
@
10.000hrs).
To
be
extended
as
additional
data
becomes
available
Reliability Demonstration
100 units running continuously for 87,600 Hrs combined
Mean Time Between Failures (MTBF)
91,440 hours as of 8/26/2013