Performance

Notes:

Preliminary measurements, they will be confirmed by third party laboratory per IESNA LM-82-11

Typical Performance @ 25°C Heatsink temperature, T

c

. See

Relative Light Output vs Temperature and LEDSense®

graphs, page 3,

for temperature & Power de-rating.

All specifications subject to tolerance of ± 10%

LEDSense

®

Operation, Thermal De-rating and Lumen

The S

R

95 employs TERRALUX’s patented LEDSense

®

Thermal Management Technology to

automatically provide maximum light output in various fixtures and operating conditions while
assuring long-term lumen maintenance. LED-Sense

®

regularly measures the operating temperature

and ensures compliance with a pre-programmed temperature and drive-current profile. This profile
is based on the LED manufacturer’s LM-80 data report and minimum L70/60,000 hour lumen
maintenance curves. LEDSense

®

is always active, and will compensate for variation in thermal

conditions due to heatsinking, ambient air, Engine positioning, or any other variable that affects the
operating temperature. The Thermal De-rating curve below identifies the relative light output that
can be expected under various thermal conditions. The LEDSense

®

Power Curve identifies the

reduction in input power over temperature.