Performance, Ledsense, Operation, thermal de-rating and lumen – TERRALUX SR95 User Manual
Page 2: The s, 95 employs terralux’s patented ledsense
![background image](/manuals/594823/2/background.png)
2
TERRALUX S
R
95 Product Specification – Subject to change without notice
WWW.TERRALUX.COM
10/01/2014
Performance
Notes:
•
Preliminary measurements, they will be confirmed by third party laboratory per IESNA LM-82-11
•
Typical Performance @ 25°C Heatsink temperature, T
c
. See
Relative Light Output vs Temperature and LEDSense®
graphs, page 3,
for temperature & Power de-rating.
•
All specifications subject to tolerance of ± 10%
LEDSense
®
Operation, Thermal De-rating and Lumen
The S
R
95 employs TERRALUX’s patented LEDSense
®
Thermal Management Technology to
automatically provide maximum light output in various fixtures and operating conditions while
assuring long-term lumen maintenance. LED-Sense
®
regularly measures the operating temperature
and ensures compliance with a pre-programmed temperature and drive-current profile. This profile
is based on the LED manufacturer’s LM-80 data report and minimum L70/60,000 hour lumen
maintenance curves. LEDSense
®
is always active, and will compensate for variation in thermal
conditions due to heatsinking, ambient air, Engine positioning, or any other variable that affects the
operating temperature. The Thermal De-rating curve below identifies the relative light output that
can be expected under various thermal conditions. The LEDSense
®
Power Curve identifies the
reduction in input power over temperature.