beautypg.com

Tests and certifications – TERRALUX L04 User Manual

Page 4

background image

 

 

4  

TERRALUX Linear Product Specification – Subject to change without notice

 

WWW.TERRALUX.COM

9/25/2014

 

Tests and Certifications

Product Safety Certifications

120V

• UL Standards 8750 (Recognized Component), 1598C (LED Retrofit Kit)
• CSA Standard C22.2 No. 250.0-08

100-277V

• UL Standards 8750 (Recognized Component), 1598C (LED Retrofit Kit)
• CSA Standard C22.2 No. 250.0-08
• ENEC License ENEC-00404 —tested according to EN 62031:2008 (Ta
55°C Tc 85°C)

Radio Frequency Emissions

• FCC Part 15, Unintentional Radiators Class A. (120V)
• FCC Part 15, Unintentional Radiators Class B. (100-277V)

Reduction of Hazardous Substances
(RoHS)

European Council Directive 2002/95/EC

Input Voltage Range/Frequency Range

120V  

90-­‐132  VAC  /  47-­‐63Hz  

100-­‐277V  

90VAC—300VAC  /  47Hz—63Hz  

Power Factor

>=  0.9

Electrical Fast Transients

IEC/EN  61000-­‐4-­‐5  ±1  kV

Surge

IEC/EN  61000-­‐4-­‐5  ±500V  Differential  mode  /  ±1  kV  Common  mode  

Voltage Harmonics

IEC/EN  61000-­‐3-­‐2

Voltage Dips and Interrupts

Mains  dips  of  30%  for  500ms,  95%  for  10ms,  and  interruptions  of  95%  
for  5s

Electrostatic Discharge

±  6  kV  Contact  mode,  ±  10  kV  Air  Gap

Shock and Vibration

Operating  –  Non  Operating

Impact

1  m  product  drop,  1.3  m  steel  ball  impact

Operating Temperature

-­‐40°C  to  +55°C,  0  to  95%  R.H.  /  153  hr

Storage Temperature

-­‐40°C  to  +85°C  /  60  hr.  followed  by    20°C  to  85°C,  5  to  95%  R.H.  /  80  hr

Ingress Protection (Water, Dust)

IP65  

Corrosive Environment

96  Hours  Salt  Fog  Test  (5%  salt  fog  at  95°C)  per  Mil-­‐Std  810F,  Method  
509.4  

Dimmer Compatibility

See  “Dimmer  Compatibility  Matrix”  

Dimming Standard Conformance

NEMA  SSL  6-­‐2010  Relative  light  output  vs.  phase  angle  (120V)  

Lumen Maintenance

L70  =60,000hr  per  IES  TM-­‐21-­‐11  (Based  on  LED  Manufacturer’s  
measurement  per  IES  LM-­‐80-­‐08  @  10.000hrs).  

Reliability Demonstration

100  units  running  continuously  for  6,700  Hrs  each

Mean Time Between Failures (MTBF)

120V - 4”: >680,000 Hrs. ; 6”: > 275,000 Hrs. ; 8”: > 400,000 Hrs.
100-277V - 4”: >530,000 Hrs. ; 6”: > 312,000 Hrs. ; 8”: > 260,000 Hrs.

This manual is related to the following products: