beautypg.com

Maintenance, Troubleshooting, Roubleshooting – CMA Dishmachines MODEL GL-C User Manual

Page 9

background image

Maintenance

6. Maintenance

6.1. Troubleshooting

PROBLEM LIKELY

CAUSE

SOLUTION

Power off at circuit breaker

Reset circuit breaker

Drive motor burn out

Replace drive motor

Obstruction in wash or rinse

Remove obstruction

Micro switch on switch support
bracket faulty or not making
contact

Replace or adjust

Conveyor doesn’t turn

Conveyor not in position

Position properly

Splash curtain not in position

Install or adjust

Washer running without any
glasses on conveyor

Keep conveyor loaded with
glasses

Spray tubes fallen off hub

Ensure spray tube is pushed
firmly on to hub connection

Excessive overspray from
hood section

Spray tubes plugged

Clear and clean with reamer,
scraper, and brush

No water in detergent tank

Ensure water supply is on
Ensure detergent tank stand
pipe is in position
Ensure the tank fill switch is in
On-Fill position and that tank
fills with water
Ensure the float switch is
activated by the float cam
Ensure the tank fill solenoid is
operational

Obstruction in wash arm

Clear obstruction

Pump not operating

Check power supply to
machine

Check pump capacitor

Replace pump if required

Lack of pressure in wash
spray tubes

Pump operating but no pressure

Check condition of impeller
and stub shaft

Replace if needed

Rinse spray tubes dirty

Clean thoroughly with reamer,
scraper, and brush provided

Shut-off valve on supply line
closed

Open valve

Lack of pressure in rinse
spray tube

Low water pressure

Minimum 25PSI flow pressure
required

MODEL GL-C Installation & Operation Manual Rev. 1.00 –2/23/06

Page

8