Maintenance
6. Maintenance
6.1. Troubleshooting
PROBLEM LIKELY
CAUSE
SOLUTION
Power off at circuit breaker
Reset circuit breaker
Drive motor burn out
Replace drive motor
Obstruction in wash or rinse
Remove obstruction
Micro switch on switch support 
bracket faulty or not making 
contact 
Replace or adjust
Conveyor doesn’t turn
Conveyor not in position
Position properly
Splash curtain not in position
Install or adjust
Washer running without any 
glasses on conveyor 
Keep conveyor loaded with 
glasses 
Spray tubes fallen off hub
Ensure spray tube is pushed 
firmly on to hub connection 
Excessive overspray from 
hood section 
Spray tubes plugged
Clear and clean with reamer, 
scraper, and brush 
No water in detergent tank
Ensure water supply is on 
Ensure detergent tank stand 
pipe is in position 
Ensure the tank fill switch is in 
On-Fill position and that tank 
fills with water 
Ensure the float switch is 
activated by the float cam 
Ensure the tank fill solenoid is 
operational 
Obstruction in wash arm
Clear obstruction
Pump not operating
Check power supply to 
machine 
Check pump capacitor
Replace pump if required
Lack of pressure in wash 
spray tubes 
Pump operating but no pressure
Check condition of impeller 
and stub shaft 
Replace if needed
Rinse spray tubes dirty
Clean thoroughly with reamer, 
scraper, and brush provided 
Shut-off valve on supply line 
closed 
Open valve
Lack of pressure in rinse 
spray tube 
Low water pressure
Minimum 25PSI flow pressure 
required 
MODEL GL-C Installation & Operation Manual Rev. 1.00 –2/23/06
Page
8