beautypg.com

Specifications – CMA Dishmachines MODEL GL-C User Manual

Page 4

background image

Specifications

2. Specifications

WATER CONSUMPTION

HOT WATER INITIAL FILL

3 GAL.

11.35 L.

HOT WATER PER HOUR (max)

12 GAL.

45.42 L.

COLD WATER PER HOUR

168 GAL.

636 L.

OPERATING CAPACITY

(2-1/2”) GLASSES PER HOUR

1000

-

WATER REQUIREMENTS

COLD WATER INLET

1/2”

-

HOT WATER INLET

1/2”

-

DRAIN CONNECTION

1-1/2”

-

TEMPERATURES

INLET COLD WATER

75

°

F 24

°

C

INLET HOT WATER (recommended)

140

°

F 60

°

C

FRAME DIMENSIONS

DEPTH 25-1/8”

63.8CM

WIDTH 25-1/4”

64CM

HEIGHT

39”-40”

99.1-101.6CM

MAX CLEARANCE FOR GLASSES

10”

25.4CM

ELECTRICAL

240 VAC

15 AMPS

TANK HEATER

(Not Booster Heater)

3KW

WASH PUMP MOTOR

.1HP

SHIPPING WEIGHT

GL-C (Approximate)

156#

71 kg

MODEL GL-C Installation & Operation Manual Rev. 1.00 –2/23/06

Page