Setpoint controls, Setpoint control – tekmar 481 User Switch User Manual User Manual
Page 3
3 of 4
© 2006
U 481 - 06/06
Example
A user switch has been installed together with two thermostats.
The thermostats are located in the master bedroom and
the guest bedroom.
User switch button 1 is labeled “Normal”.
User switch button 2 is labeled “Guest”.
User switch button 3 is labeled “Away”.
The master bedroom is programmed to operate at the
programmable setback schedule while in “Normal” and
“Guest” scenes.
The guest thermostat is programmed to operate at the
unoccupied temperature while in “Normal” scene and at the
programmable setback schedule while in “Guest” scene.
In this example, when a guest arrives to stay the night, the
“Guest” button can be pressed and the Guest Bedroom
temperature will operate on a programmable setback
schedule.
Once the guest leaves, press the “Normal” button to lower the
Guest Bedroom to the unoccupied temperature setting.
The following table shows how the thermostats respond
to each button:
Button
Master Bedroom
Action
Guest Bedroom
Action
“Normal”
Setback Schedule
Unoccupied
“Guest”
Setback Schedule
Setback Schedule
“Away”
Away
Away
Setpoint Controls
In addition to scenes, the user switch can also be programmed
to enable and disable individual setpoint controls or groups
of setpoint controls by pressing the user switch button.
These controls can regulate the temperature of devices
such as a hot tub or a radiant floor.
When a user switch button configured for setpoint controls
is pressed, the setpoint control changes the operational
setpoint from the unoccupied to the occupied temperature.
The setpoint control has a timer setting that counts down,
and when the timer expires, the setpoint device changes
back to the unoccupied temperature. Also, if the user switch
button is pressed a 2nd time, the setpoint device operation
changes back to the unoccupied temperature.
Press the “Hot Tub” button and the Hot Tub operates
for the set time.
COLD
User
Button
1
User
Button
2
User
Button
3
UnOcc
Setpoint
Control
Press the “Hot Tub” button while the Setpoint Control is
running to disable the Hot Tub.
User
Button
1
User
Button
2
User
Button
3
HOT
Set Time
3:00 hr
Setpoint
Control
User
Button
1
User
Button
2
User
Button
3
HOT
Run Time
2:17hr
Setpoint
Control
COLD
User
Button
1
User
Button
2
User
Button
3
UnOcc
Setpoint
Control