Revision 02
TM 7165
Edition 06/2008
6
Installation
Examine valve for in-transit damage, damaged ball 
valves must not be installed. 
Before installation the valve and the connecting 
pipe must be carefully cleaned to remove any dirt, 
especially hard foreign matter. 
During installation, pay attention to the correct 
tightening torque, aligned pipes and tension-free 
assembly. 
It must be ensured that the lever swings freely 
(dead man's position). 
Ensure that a remotely actuated actuator 
cannot be accidentally switched on. 
6.1 Flange caps and gaskets
Leave protective caps on the flanges until just prior 
to installation. 
Where there is a particularly high risk of damage to 
the plastic sealing surfaces, e.g. if the mating flanges 
are made of metal are glass-lined, PTFE-lined gaskets 
with a metal inlay should be used. These gaskets are 
available as special accessories in the Richter range. 
 
6.2 Direction of flow and
installation position
Installation is independent of the direction of flow. 
The installation position is normally horizontal with the 
bottle connection pointing vertically downwards 
(deviations from this position require a special bottle 
connection). See Section 10.4 and 10.9.
6.3 Grounding
The valve must be grounded. The simplest solution is 
to use tooth lock washers which are placed under one 
pipe bolt of each flange. 
Otherwise grounding must be ensured by different 
measures e.g. a cable link. 
At the customer's request a setscrew M6 with a hex. 
nut and washer will be provided at each flange as an 
additional grounding connection.
6.4 Test
pressure
The test pressure PT of an open valve must not 
exceed the value of 1.5 x PS(PN) as per the 
identification of the valve. 
 
6.5 Star
knop
The stroke and thus the pressure reduction and 
medium flow can be influenced with the star knob. 
Moreover, the star knob can be used to close the 
valve like a manual valve. 
It also served to enforce tightness in case of damaged 
seat sealing surfaces or seized particles. 
 
6.6 High-viscosity media / Low
operating pressure
With the version "design for high-viscosity media" the 
changed operating limits acc. to the name plate must 
be observed and the travel must be set according to 
the setting instructions in Section 6.7.
6.7 Setting instructions
Press the sampling lever in the direction of the 
valve. 
Slowly turn the star knob counterclockwise until the 
flow into the sampling bottle corresponds to the 
intensity you want. 
Release lever and lock the star knob in this 
position. 
This procedure guarantees that with each further 
sampling process (with the same internal pressure) 
the flow of the sample into the bottle remains within 
the desired range without any risk to the person taking 
the sample. 
If the operating pressures vary, we recommend you 
for safety's sake to turn the star knob after every 
sampling operation clockwise again until it reaches 
zero point (lever cannot execute any travel). 
 