CONTROL PANEL AND BASIC OPERATION:
Power Input:
The power required to operate the
Studio Max II
is 105 to 125 volts AC, 50/60
Hz, 4 Amp, and/or, for a B model, an approved DC battery power pack. The power
cord has a 125V, 10 Amp. rating. Replacement cords or extension cords rated for
less amperage may overheat and should not be used with PowerLights.
Circuit Protection:
Circuit protection (fuse) automatically protects this appliance from excessive
damage due to circuit or component failure. Operation exceeding the rated cycle of
the appliance may cause the fuse to open. [Always replace fuse with same rating of
fuse.]
To replace a blown fuse (power cord must be disconnected), simply unscrew the
fuse holder cap (side front of unit) and replace the exposed fuse with a new fuse. If
fuses continue to blow, contact your dealer or qualified service person. (See
specification section for fuse replacements)