Fixture Operation
Warning! To Ensure Proper Operation
ALWAYS TURN OFF THE FIXTURE BEFORE connecting or disconnecting lamps.
After the lamps are properly installed, the switch can turn on the fixture. Avoid
operating in temperatures above 125°F (51°C) or below 60°F (15°C).
Cold Temperature Operation
In cold temperatures below 60°F or 15°C, the fixture may not strike. If lamps
do not strike within 5 seconds, switch the fixture to OFF and try again. Check
that the lamps are properly seated and the dimmer is up full, then restrike.
If temperatures are too low, try to warm up the fixture to at least 60°F (15°C).
Lamps will turn on at preset dimmer settings as long as the temperature is above
60°F or 15°C.
Imara DMX Control Panel
A) DMX Dim Channels: Sets the fixture to use 1 DMX channel to dim all
10 lamps or 5 DMX channels to control lamps in sets of 2.
(Imara S6 has 1 or 3 DMX channels.)
B) DMX Address: Sets DMX address of fixture.
C) DMX Indicator: Lights if valid DMX signal is present.
D) DMX-In & DMX-Out: DMX-In receives signals from Dimmer Board.
DMX-Out relays DMX signal through to other fixtures or instruments.
(Note: Each Imara fixture has an “
AUTO TERMINATE” feature.
The last fixture that does not have an XLR cable attached to the
DMX “Out” port will automatically terminate.)
E) Fuse: Provides circuit protection. Note: If fuse is “blown” or “open”,
replace with same type of fuse rating as marked.
F) Power Switch: Turns fixture on and off. Has built-in indicator light to
detect if AC power is present in power cord. “O” = OFF position.
G) Dimmer Knob: Manual dimming control
H) Lamp Select Switches: Turns lamps on manually in sets of 2.
A
B
C
D
F
E
G
Note: The Imara S10 is shown throughout this operation manual for example purposes.