beautypg.com

Bloomfield 2088EX User Manual

Page 10

background image

PROGRAMMING FEATURES AND OPTIONS


1. View Water Temperature in Tank: To view the water temperature on the screen, the E-Max™
brewer must be ON, and not brewing or in the filling mode. Press and hold the 4th key, and
depress the 6th key. The actual water temperature will be displayed for 3 seconds.


2. Daily Brew Count: The E-Max™ maintains a count of the number of completed brews for a
7-day period. To access the count, turn the brewer OFF. In the OFF mode, press and hold the
CANCEL key for 3 seconds. The current day and brew count will be displayed. Depress the
ON/OFF key repeatedly to view each preceding day. When all 7 days have been displayed a
7-day total will be displayed. If you wish to exit the daily brew count before viewing all of the
days, press CANCEL key.


3. ON/OFF – Non Automatic Timer: To turn the brewer OFF, press the ON/OFF switch: 2 beeps
will be heard and the brewer will be turned OFF, indicated by all lights being off. To turn the
brewer ON, press the ON/OFF switch: 2 beeps will sound, all lights will flash once, then the
“Power” light will remain on, (the “Heat” light may come on if water temperature is too low).


4. ON/OFF – Automatic Timer Feature: The factory programmed E-Max™ has the automatic
timer turned off. To set the automatic timer, refer to the E-Max™ Programming Manual, “Time
Functions” Menu. If the Automatic Timer feature is programmed off, the brewer can be turned
on and off by depressing the ON/OFF switch, as noted above.
* When the Automatic Timer feature is programmed ON, the E-Max will turn on and off
automatically, at a programmed time, Monday to Friday; with a separate on and off
programmed time schedule for Saturday and Sunday.
* Temporarily Overriding the Automatic ON/OFF function. While in the automatic timed OFF
mode the brewer can be started by depressing the ON/OFF switch. The brewer will remain
ON until the automatic programmed off time, when it will turn OFF and resume normal
automatic timed functioning. Similarly, if turned OFF during the automatic timed ON mode
the brewer will remain OFF until the next programmed on time, when it will turn on and
resume normal automatic timed functioning.


5. Automatic Start-Up in Previous Mode: If the E-Max™ automatic timer is OFF (the factory
setting) and power is disconnected, the brewer will start up when power is restored, in the mode
it had been in prior to the power disconnection. If the E-Max™ has the timer setting ON and
power is disconnected, the brewer will start up in the mode that it should be in at the time the
power is restored.


6. Viewing Programmed Brew Volume:
The E-Max™ can have up to 4 different brew volumes.
When a volume other than the standard, or first brew volume, is selected, the E-Max™ will
complete that volume and then automatically reset to the standard, or first brew volume. With the
brewer ON, press and hold the CANCEL key. The 1st, or standard, volume will be displayed for
3 seconds (i.e. Volume #1 64 oz)., and then the day and time will be displayed.


7. Changing Brew Volume: As outlined above, display the current brew volume and, before the
display changes to day and time, depress the CANCEL key momentarily, (not for 3 seconds).
The next programmed brew volume (e.g. Volume#2 32 oz.) will be displayed on the LCD for
3 seconds, after which the display will return to the day and time. Repeatedly press CANCEL
while programmed volumes are shown to view all brew volumes. (If there is only one brew
volume programmed, only that volume will be displayed.) The last brew volume displayed, before
the LCD returns to the day and time, is the brew volume that the E-Max™ will brew the next time
the BREW switch is depressed. When a brew volume other than the 1st brew volume is
selected, the E-Max™ will complete the brew then return to the 1st or standard brew volume
automatically.

OPERATION (continued)

8

This manual is related to the following products: