beautypg.com

Gossen Sixtomat flash User Manual

Page 12

background image

12

GOSSEN Foto- und Lichtmeßtechnik GmbH

3.2.4 Contrast measurement

– Select

with the function buttons

– Keep the measuring button

depressed

while aiming the meter at various areas of the
subject. The analog aperture scale displays
the f-stop series between two extreme values,
and with the actual measured value flashing.
The first measured f-stop is displayed on the
left-hand side of the display (it remains dis-
played as a reference value (e.g. of a
grey card)).

– After the measuring button is released, the

entire measured contrast range is displayed
on the analog aperture scale, and the last
measured value will cease to flash.

3.2.5 Aperture priority mode

– Select

with the function buttons

– Set the desired aperture with the value but-

tons. The intermediate 1/10 stop values stored
from the last measurement appear when the
aperture is preset. These are invalid because
the valid 1/10th stops will only appear after the
next meter reading is taken.

– Measure by pressing the meas. button
– The measured shutter speed appears on the

right-hand digital display

– Automatic adaptation of the aperture

in 1/10 stops to the measured shutter speed

– Select other paired aperture/shutter values

with the value buttons

t

M

f

M