4 servicing and repairs, 5 technical data – Gossen Digipro F User Manual
Page 7

GOSSEN Foto- und Lichtmesstechnik GmbH
7
4
Servicing and Repairs
No special maintenance is required, if the Digipro F is handled correctly.
Keep the outside surface clean. Use a slightly dampened cloth for cleaning. Do not use cleansers, abrasives or
solvents.
Should the meter nevertheless not work to your satisfaction,please send the Digopro F to:
GOSSEN Foto- und Lichtmesstechnik GmbH
Thomas-Mann-Str.16-20
D-90471 Nürnberg
or to the GOSSEN Agency in your country
Phone : +49 911 8602-181
Fax:
: +49 911 8602-142
e-mail: [email protected]
5
Technical Data
Measuring methods
Incident light / Reflected light / Contrast measurement
Flash (cord/noncord)
Indication of ambient light share
Calculation for multiple flash
Programmable exposure correction
Sensor
Silicon blue cell photodiode
Measuring range
LW –2.5 to +18 (with ISO 100/21 °)
Repeatable accuracy
±0.1 EV
Exposure times
1/8000 s to 60 min
Aperture stops
f/1 to f/90 9/10
Measuring range flash
f/1 to f/90 (with ISO 100/21°)
Flash synch speeds
1 to 1 /1000 including 1/90 s (meas. time)
CINE values
8 to 64 including 25 and 30 TV)
Adjustable and measurable correction values
–7.9 to +7.9
Extension factors
1.0 to 240
Film speeds
ISO 3.2/6° to 8000/40°
Acceptance angle for reflected light
25°
Battery
1 x 1.5 V AA-type, battery condition indication
Accessories
Case, neck strap, battery and operating instructions
Dimensions
ca. 65 x 118 x 19 mm
Weight
ca. 95 g (without battery)
Electromagnetic Compatibility (EMC): The Digipro F meets the Specifications 89/336/EWG dt. 01.01.1996