Trouble shooting, Commercial outdoor heater – Garden Sun Heater HS-SS Commercial Square User Manual
Page 18
18
COMMERCIAL OUTDOOR HEATER
TROUBLE SHOOTING
PROBLEM 2
Large Yellow Candling Flame
CAUSE
This can occur after a period of non-use. Most likely
debris, dirt or a spider web has gotten into the orifice.
SOLUTION
CLEAN THE ORIFICE
1. Remove the hood and emitter by removing the (4)
screws that attach the emitter screen to the burner plate.
2. For easier access, also remove the top section of the
post. This can be accomplished by first removing the
regulator from the hose. Then remove the top neck
portion from the post.
3. With phillips screwdriver, remove the four screws
holding the burner plate to the powder coated neck post.
Pull the burner plate away from the post neck and slightly
tilt to the side. Be careful not to crimp any tubes or wires.
Damaging any tubes may create a leak.
4. The Orifice will now be exposed.
5. Examine for debris, dirt or spider webs and clean as
necessary.
* Make sure not to push obstruction farther down orifice.
6. Once cleaned, re-assemble burner plate to neck post,
making sure all wires and tubes are safely slid back into
the neck. Re-tighten the four screws in place.
7. Re-attach Top Neck Post to rest of heater assembly..
Attach regulator to gas hose. Make sure to use teflon tape
when re-attaching regulator.
8. Check for leaks (refer to Solution for Problem 1, Cause
A).
9. Re-light heater to test.
Please also reference the Instruction Manual for any
reference to assembly.
1
2
REMOVE THE (4) SCREWS
HOLDING THE BURNER PLATE
TO THE POST NECK, PULL BURNER
PLATE AWAY AND TILT TO ACCESS
ORIFICE
3
ORIFICE