Feed Water Guidelines

pH . . . . . . . . . . . . . . . . . . . . . . . 6 to 10
Hardness (maximum) . . . . . . . . . Depends on customers acceptable

hardness leakage level.

Water Pressure . . . . . . . . . . . . . 25psi to 125psi (171 kPa to 8.5 bar)
Temperature . . . . . . . . . . . . . . . 34 - 110°F (1 - 43°C)
Free Chlorine (maximum) . . . . . . 1mg/L
Iron (maximum) . . . . . . . . . . . . . 1mg/L
Oil and H2S . . . . . . . . . . . . . . . . None Allowed
Turbidity . . . . . . . . . . . . . . . . . . Less than 5.0 NTU

For all other guideline information please contact your Watts

representative.

Specifications

Mineral Tank

Brine Tank

SofTening

lBS. SalT Per

flow raTe & PreSSure

Tank reSin graVel Tank

SalT

CaPaCiTY

regeneraTion

SerV

DroP

Bkw

MoDel

SiZe

ft

3

#20

SiZe

fill

Max

Min

Max

Min

gPM

PSi

gPM

M4410W

12x52

2.0

30 lbs.

18x40

400

60 K

40 K

30

12

28/38

15/25

4.0

M4414W

14x65

3.0

60 lbs.

18x40

400

90 K

60 K

45

18

33/44

15/25

5.0

M4418W

16x65

4.0

80 lbs.

18x40

400

120 K

80 K

60

24

36/50

15/25

7.0

M4422W

18x65

5.0

100 lbs.

24x41

600

150 K

100 K

75

30

40/54

15/25

11.0

M4426W

21x62

7.0

100 lbs.

24x41

800

210 K

140 K

105

42

43/58

15/25

13.0

M4430W

24x72

10.0 200 lbs.

30x50

1400

300 K

200 K

150

60

45/60

15/25

15.0

Note: Capacities are based on resin manufacturer’s data and are dependent upon influent water TDS, temperature, bed depth, and

flow rates. Feed water must be free of oil and color. Pipe size, tank size, and space requirements are in inches. Capacities and flow rates

expressed above are per tank. Flow rates listed at 25psi drops are for intermittent peak flow rates and are not to be used as continuous flows.
Note: Flow rates listed above are based on pressure drop only. Selecting a system based on pressure drop alone does not guarantee that

the system will proved adequately softened water. System selection should be based on resin quantity, capacity required, feed water analy-

sis, and application requirements.

ES-WQ-CWS150 1306

© 2013 Watts

USA: Tel. (800) 659-8400 • www.watts.com

Canada: Tel. (888) 208-8927 • www.watts.ca

A Watts Water Technologies Company

Note: Do not use with water that is microbiologically unsafe or of

unknown quality without adequate disinfection before or after the

system.

Dimensions - Weight

CwS150 SerieS

oVerall

oVerall

oVerall

MoDel

Tank

in

ouT

HeigHT

DePTH

wiDTH

Brine Tank

M4410W

12"X52"

56.3" 56.3" 63.3" 13.0" 16.7" 18"X40"

M4414W

14"X65"

68.4" 68.4" 74.3" 14.1" 17.8" 18"X40"

M4418W

16"X65"

67.8" 67.8" 73.7" 16.1" 18.7" 18"X40"

M4422W

18"X65"

70.3" 70.3" 76.2" 18.1" 20.8" 24"X41"

M4426W

21"X62"

70.1" 70.1" 76.1" 21.1" 21.2" 24"X41"

M4430W

24"X72"

77.3" 77.3" 83.2" 24.1" 24.1" 30"X50"

Note: This information is not intended to replace the product installation and safety information available or the experience of a trained prod-

uct installer. Please refer to the product installation and safety instructions for further information.

Ordering Information

MoDel

DeSCriPTion

PiPe SiZe

SPaCe reQuireD

weigHT

lBS kgS

M4410W

A0060FM150WE with turbine flow meter

1.5"

24 x 44 x 75

210 95

M4414W

A0090FM150WE with turbine flow meter

1.5"

24 x 44 x 87

240 109

M4418W

A0120FM150WE with turbine flow meter

1.5"

24 x 44 x 87

320 145

M4422W

A0150FM150WE with turbine flow meter

1.5"

24 x 50 x 87

380 172

M4426W

A0210FM150WE with turbine flow meter

1.5"

24 x 52 x 84

585 265

M4430W

A0300FM150WE with turbine flow meter

1.5"

39 x 69 x 96

710 322