Filter Cartridge Replacement Procedure

IMPORTANT: Determine whether all equipment connected to

the OneFlow

®

system must be turned off prior to shutting off

water supply from filters.
1. If required, turn off equipment.
2. Turn OFF water to OneFlow

®

system by closing Inlet Ball Valve.

3. Press the red button to release pressure.
4. Remove housing(s) – use filter wrench if necessary.
5. Clean inside of housing sump with warm water. If desired,

disinfect housing using a teaspoon of household bleach.

Add to filter bowl and add water. Let stand 5 minutes, and

then discard.

6. Insert new cartridge into filter housing. Match cartridge

model numbers to model numbers on bracket.

7. Make certain the O-ring is properly positioned and reinstall

filter housing (hand tighten only). Check O-ring for damage

and replace if damaged or distorted.

8. Slightly open the inlet ball valve; push the red pressure relief but-

ton to release trapped air until a small amount of water comes

out – release the red button and fully open the ball valve.

9. Open the flush valve downline from the filter housing (if

equipped) and flush the new cartridge to drain or bucket

for two minutes or until water runs clear. If no flush valve is

present, disconnect line from equipment to flush to drain.

10. VERY IMPORTANT: With water supply inlet valve OPEN and

water flow confirmed, turn on connected equipment. Failure

to supply water to equipment may cause serious damage.

11. Record filter change on the service log.

8.

4.

7.

6.

3.

2.

Maintenance

Routine maintenance of your OneFlow

®

system involves periodic filter

cartridge changes and/or replacement of sump O-rings. If the system

sizing recommendations have been followed, the OneFlow

®

Cartridge

OF120RM should last one year.

Filter Change Frequency

The filters should be changed in response to the following conditions.
OF120RM • 12 months since installation or last filter change.

Replacement Filter Cartridges

OneFlow

®

systems can only be used with OneFlow

®

filter car-

tridges. Use of replacement cartridges other than those specified

will void warranties, certifications and may compromise equipment

protection, water quality and equipment life.

Operation

With sufficient pressure, operation of the OneFlow

®

system is

completely automatic. Dependable operation involves only peri-

odic filter changes and service documentation.