Filter Cartridge Replacement Procedure
IMPORTANT: Determine whether all equipment connected to
the OneFlow
®
system must be turned off prior to shutting off
water supply from filters.
1. If required, turn off equipment.
2. Turn OFF water to OneFlow
®
system by closing Inlet Ball Valve.
3. Press the red button to release pressure.
4. Remove housing(s) – use filter wrench if necessary.
5. Clean inside of housing sump with warm water. If desired,
disinfect housing using a teaspoon of household bleach.
Add to filter bowl and add water. Let stand 5 minutes, and
then discard.
6. Insert new cartridge into filter housing. Match cartridge
model numbers to model numbers on bracket.
7. Make certain the O-ring is properly positioned and reinstall
filter housing (hand tighten only). Check O-ring for damage
and replace if damaged or distorted.
8. Slightly open the inlet ball valve; push the red pressure relief but-
ton to release trapped air until a small amount of water comes
out – release the red button and fully open the ball valve.
9. Open the flush valve downline from the filter housing (if
equipped) and flush the new cartridge to drain or bucket
for two minutes or until water runs clear. If no flush valve is
present, disconnect line from equipment to flush to drain.
10. VERY IMPORTANT: With water supply inlet valve OPEN and
water flow confirmed, turn on connected equipment. Failure
to supply water to equipment may cause serious damage.
11. Record filter change on the service log.
8.
4.
7.
6.
3.
2.
Maintenance
Routine maintenance of your OneFlow
®
system involves periodic filter
cartridge changes and/or replacement of sump O-rings. If the system
sizing recommendations have been followed, the OneFlow
®
Cartridge
OF120RM should last one year.
Filter Change Frequency
The filters should be changed in response to the following conditions.
OF120RM • 12 months since installation or last filter change.
Replacement Filter Cartridges
OneFlow
®
systems can only be used with OneFlow
®
filter car-
tridges. Use of replacement cartridges other than those specified
will void warranties, certifications and may compromise equipment
protection, water quality and equipment life.
Operation
With sufficient pressure, operation of the OneFlow
®
system is
completely automatic. Dependable operation involves only peri-
odic filter changes and service documentation.