Models, Replacement cartridge, Specifications – Watts OF240-4 User Manual

Page 2: Dimensions — weights water chemistry & limitations, Standards

background image

Models

Model

Maximum Flow Rate Connection Sizes

OF210 – 1

1 gpm (4 lpm)

1

2

” (15mm) FNPT

OF220 – 2

2 gpm (8 lpm)

1

2

” (15mm) FNPT

OF240 – 4

4 gpm (15 lpm)

3

4

” (20mm) FNPT

Replacement Cartridge

OF110RM Cartridge should be replaced every 12 months
OF120RM Cartridge should be replaced every 12 months
OF140RM Cartridge should be replaced every 12 months
OF110RC

Cartridge should be replaced every 6 months

OF120RC

Cartridge should be replaced every 6 months

OF140RC

Cartridge should be replaced every 6 months

Specifications

A OneFlow

®

scale prevention system with added carbon filtra-

tion shall be installed on the cold water service line to condition

and filter the tap water just prior to the service line feeding the

equipment it is designed to protect. The system will be sized

for maximum or peak flow rate based on the specification of

said equipment. A OneFlow

®

system with added carbon filtra-

tion may also be installed to protect multiple pieces of equip-

ment from the ill-effects of hard water scale and taste/odor

concerns provided the aggregate peak flow rate for each piece

of equipment it is protecting has been considered. The system

shall be plumbed with a bypass valve to allow isolation of filter

housings to allow the bypass of untreated water in the event

that service or cartridge replacement is necessary. The instal-

lation area should be suitable in size for the housing to be ser-

viced without encumbrance and the system should be installed

per the Installation, Operation & Maintenance manual as pro-

vided with each system.
The OneFlow

®

system must not require additional waste water

to backwash, flush, or regenerate once put into service. The

system shall not require any chemical additives and shall not

require electricity for operation.

Note: Copper lines need to be passivized for a minimum

of 4 weeks before placing unit into service. Not for use on

closed loop systems.

Dimensions — Weights

Water Chemistry & Limitations

pH

6.5 to 8.5

Hardness (maximum)

75 grains (1300 ppm CaCO3)

Temperature

41°F to 100°F (5° to 38°C)

Chlorine

<

3ppm

Iron (maximum)

0.3 mg/l

Manganese (maximum)

0.05 mg/l

Copper

none allowed

Oil & H2S

none allowed

Polyphosphate

none allowed

Silica (maximum)

10 ppm

Standards

Independent scientific testing has confirmed Template Assisted

Crystallization (TAC) technology provides scale reduction of over

95+%. Testing was conducted under protocol based on DVGW

W512 test to access control of scale formation.

Clearance

A

A

C

D

B

E

Model

Dimensions

Weight

A

B

C*

D

E*

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

lbs.

kgs.

OF210-1

14

1

2

37

9

1

4

24

5

1

8

13

11

1

4

29

5

3

4

15

9

4.1

OF220-2

24

1

2

62

9

1

4

24

5

1

8

13

11

1

4

29

5

3

4

15

14

6.4

OF240-4

26

66

15

1

4

39

8

5

8

22

17

5

16

44

12

1

4

31

31

14.1

The overall height and the height of the fitting varies due to material variations and assembly

tolerances. Please allow additional clearances above the tank for making connections.

ES-OF210_220_240 1140

© 2011 Watts

USA: No. Andover, MA • Tel: (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com

Canada: Burlington, ON • Tel: (905) 332-4090 • Fax: (905) 332-7068 • www.wattscanada.ca

A Watts Water Technologies Company