Models, Replacement cartridge, Specifications – Watts OF240-4 User Manual
Page 2: Dimensions — weights water chemistry & limitations, Standards
Models
Model
Maximum Flow Rate Connection Sizes
OF210 – 1
1 gpm (4 lpm)
1
⁄
2
” (15mm) FNPT
OF220 – 2
2 gpm (8 lpm)
1
⁄
2
” (15mm) FNPT
OF240 – 4
4 gpm (15 lpm)
3
⁄
4
” (20mm) FNPT
Replacement Cartridge
OF110RM Cartridge should be replaced every 12 months
OF120RM Cartridge should be replaced every 12 months
OF140RM Cartridge should be replaced every 12 months
OF110RC
Cartridge should be replaced every 6 months
OF120RC
Cartridge should be replaced every 6 months
OF140RC
Cartridge should be replaced every 6 months
Specifications
A OneFlow
®
scale prevention system with added carbon filtra-
tion shall be installed on the cold water service line to condition
and filter the tap water just prior to the service line feeding the
equipment it is designed to protect. The system will be sized
for maximum or peak flow rate based on the specification of
said equipment. A OneFlow
®
system with added carbon filtra-
tion may also be installed to protect multiple pieces of equip-
ment from the ill-effects of hard water scale and taste/odor
concerns provided the aggregate peak flow rate for each piece
of equipment it is protecting has been considered. The system
shall be plumbed with a bypass valve to allow isolation of filter
housings to allow the bypass of untreated water in the event
that service or cartridge replacement is necessary. The instal-
lation area should be suitable in size for the housing to be ser-
viced without encumbrance and the system should be installed
per the Installation, Operation & Maintenance manual as pro-
vided with each system.
The OneFlow
®
system must not require additional waste water
to backwash, flush, or regenerate once put into service. The
system shall not require any chemical additives and shall not
require electricity for operation.
Note: Copper lines need to be passivized for a minimum
of 4 weeks before placing unit into service. Not for use on
closed loop systems.
Dimensions — Weights
Water Chemistry & Limitations
pH
6.5 to 8.5
Hardness (maximum)
75 grains (1300 ppm CaCO3)
Temperature
41°F to 100°F (5° to 38°C)
Chlorine
<
3ppm
Iron (maximum)
0.3 mg/l
Manganese (maximum)
0.05 mg/l
Copper
none allowed
Oil & H2S
none allowed
Polyphosphate
none allowed
Silica (maximum)
10 ppm
Standards
Independent scientific testing has confirmed Template Assisted
Crystallization (TAC) technology provides scale reduction of over
95+%. Testing was conducted under protocol based on DVGW
W512 test to access control of scale formation.
Clearance
A
A
C
D
B
E
Model
Dimensions
Weight
A
B
C*
D
E*
in.
mm
in.
mm
in.
mm
in.
mm
in.
mm
lbs.
kgs.
OF210-1
14
1
⁄
2
37
9
1
⁄
4
24
5
1
⁄
8
13
11
1
⁄
4
29
5
3
⁄
4
15
9
4.1
OF220-2
24
1
⁄
2
62
9
1
⁄
4
24
5
1
⁄
8
13
11
1
⁄
4
29
5
3
⁄
4
15
14
6.4
OF240-4
26
66
15
1
⁄
4
39
8
5
⁄
8
22
17
5
⁄
16
44
12
1
⁄
4
31
31
14.1
The overall height and the height of the fitting varies due to material variations and assembly
tolerances. Please allow additional clearances above the tank for making connections.
ES-OF210_220_240 1140
© 2011 Watts
USA: No. Andover, MA • Tel: (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com
Canada: Burlington, ON • Tel: (905) 332-4090 • Fax: (905) 332-7068 • www.wattscanada.ca
A Watts Water Technologies Company