Models replacement parts – Watts PWUVQ User Manual
Page 2
![background image](/manuals/589671/2/background.png)
ES-WQ-PWUV 1225
© 2012 Watts
USA: Tel. (800) 224-1299 • www.watts.com
Canada: Tel. (888) 208-8927 • www.watts.ca
A Watts Water Technologies Company
Model No.
Flow Rate
PiPe Size
diMeNSioNS
electRical
ShiPPiNg weight
(gPM)
(l X w X h)
lbs.
kgs.
PWUV2110
2
1/2" MNPT
18" x 6" x 5-3/8"
110-130 v / 50-60 Hz
6
3
PWUV2220
2
1/2" MNPT
18" x 6" x 5-3/8"
200-250 v / 50-60 Hz
6
3
PWUV6110
6
3/4" MNPT
25-1/2" x 6" x 5-3/8"
110-130 v / 50-60 Hz
7
3
PWUV6220
6
3/4" MNPT
25-1/2" x 6" x 5-3/8"
200-250 v / 50-60 Hz
7
3
PWUV8110
8
3/4" MNPT
32" x 8-1/4" x 3-3/4"
110-130 v / 50-60 Hz
9
4
PWUV8220
8
3/4" MNPT
32" x 8-1/4" x 3-3/4"
200-250 v / 50-60 Hz
9
4
PWUV12110
12
1" MNPT
41-1/2" x 8-1/4" x 3-3/4"
110-130 v / 50-60 Hz
17
8
PWUV12220
12
1" MNPT
41-1/2" x 8-1/4" x 3-3/4"
200-250 v / 50-60 Hz
17
8
Flow Rate (gPM)
BUlB Model
BallaSt Model
QUaRtz SleeVe Model
2
PWUVBULB2
PWUVBAL2
PWUVQS2
6
PWUVBULB6
PWUVBAL6-12
PWUVQS6
8
PWUVBULB8
PWUVBAL6-12
PWUVQS8
12
PWUVBULB12
PWUVBAL6-12
PWUVQS12
Models
Replacement Parts
Specifications
Chamber materials
304SS
Max. water temperature
104°F (40°C)
Min. water temperature
36°F (2°C)
Max pressure
125psi
UV dose (end of life)
30 mj/cm2
Lamp life
9,000 hrs
Lamps per chamber
Single
Water Quality Guidelines
Total Iron
less than 0.3 mg/l
Hydrogen sulfide
less than 0.05 mg/l
Turbidity
less than 1.0 NTU
Manganese
less than 0.05 mg/l
Hardness
less than 7 grains
UV transmittance
greater than 90%
Note: Minimum water quality guidelines are recommended to ensure proper
operation and continuous disinfection.