Equipment Specifications

Watts OneFlow

®

systems are complete, self-contained, loaded

with media and ready to use. A simple inlet and outlet connec-

tion is all that is required for installation. Please review operat-

ing pressures, temperatures and water chemistry limitations to

ensure compatibility.

Specifications

Inlet/Outlet Connection

3

/

4

" - 1

1

/

4

" (multiple options)

Temperature

40° - 110°F

pH

6.5 to 8.5

Ferrous Iron, Max*

0.3 mg/L

Manganese, Max*

0.05 mg/L

Copper, Max*

1.3 mg/L

Water Pressure (psi)

15psi min., 100psi max

* See note about iron, manganese and copper on the next page.

a

b

c

e

d

Mechanical Specifications

Model

744

844

948

1054

1252

Max Service Flow
(gpm)

10

12

16

20

30

Dry Weight (lbs)

22

25

29

35

43

Service Weight (lbs)

80

97

129

168

235

Dimensions

(nominal - inches)

a

47

47

49

58

55

b

46

46

48

57

54

c

7

8

9

10

12

d

1.0

1.0

1.0

1.0

1.0

e

3.0

3.0

3.0

3.0

3.0

Using OneFlow

®

with other water treatment

equipment.

Due to the unique properties of OneFlow

®

, there are some

unique requirements for using OneFlow

®

in conjunction with filtra-

tion or other forms of water treatment.
1. OneFlow

®

must be the last stage in the treatment chain. Do

not install any filters after OneFlow

®

or before any devices for

which scale prevention is required. POU drinking water filters,

e.g. carbon or RO are exempt from this requirement.

2. Do not apply phosphate or any other antiscalant either before

or after OneFlow

®

.