beautypg.com

Specifications, Ordering information – Watts PWS15T (3-10CUFT) User Manual

Page 3

background image

ES-WQ-PWS15T 1136

© 2011 Watts

USA: North Andover, MA • Tel. (800) 224-1299 • www.watts.com

Canada: Burlington, ON • Tel. (888) 208-8927 • www.wattscanada.ca

A Watts Water Technologies Company

Specifications

MiNerAl TANK

BriNe TANK

soFTeNiNG

lBs. sAlT Per

FloW rATe & Pressure

TANK resiN GrAVel TANK

sAlT

CAPACiTY

reGeNerATioN

serV

droP

BKW

Model No.

siZe

Ft

3

siZe

Fill

MAx

MiN

MAx

MiN

GPM

Psi

GPM

PWS15T171C21

12" x 52"

2.0

30 lbs. 24" x 41"

600

60 K

40 K

30

12

15/20

15/25

5.0

PWS15T171D21

14" x 65"

3.0

60 lbs. 24" x 41"

600

90 K

60 K

45

18

17/22

15/25

7.0

PWS15T171E21

16" x 65"

4.0

80 lbs. 24" x 41"

600

120 K

80 K

60

24

25/40

15/25

9.0

PWS15T171F21

18" x 65"

5.0

100 lbs. 24" x 41"

600

150 K

100 K

75

30

30/50

15/25

12.0

PWS15T171G21

21" x 62"

7.0

100 lbs. 24" x 50"

800

210 K

140 K

105

42

35/53

15/25

15.0

PWS15T171H21

24" x 72" 10.0

200 lbs. 30" x 50"

1200

300 K

200 K

150

60

40/55

15/25

15.0

Ordering Information

sPACe

Model No.

desCriPTioN

PiPe siZe

reQuired

WeiGHT

W x d x H

lBs

KGs

PWS15T171C21

2 Cubic Foot Twin Alt. Water Softener with Flow Meter

1

1

2

"

24" x 42" x 75"

370 168

PWS15T171D21

3 Cubic Foot Twin Alt. Water Softener with Flow Meter

1

1

2

"

24" x 44" x 87"

550 250

PWS15T171E21

4 Cubic Foot Twin Alt. Water Softener with Flow Meter

1

1

2

"

24" x 46" x 87"

720 327

PWS15T171F21

5 Cubic Foot Twin Alt. Water Softener with Flow Meter

1

1

2

"

24" x 50" x 89"

900 409

PWS15T171G21

7 Cubic Foot Twin Alt. Water Softener with Flow Meter

1

1

2

"

24" x 52" x 89"

1215 552

PWS15T171H21

10 Cubic Foot Twin Alt. Water Softener with Flow Meter

1

1

2

"

39" x 69" x 96"

1750 795

Notes: Capacities are based on resin manufacturer’s data and are dependent upon influent water TDS, temperature, bed depth, and

flow rates. Feed water must be free of oil and color. Pipe size, tank size, and space requirements are in inches. Capacities and flow

rates expressed above are per tank. Flow rates listed at 25 psi drops are for intermittent peak flow rates and are not to be used as

continuous flows.

Note: This information is not intended to replace the product

installation and safety information available or the experience of

a trained product installer. Please refer to the product installa-

tion and safety instructions for further information.

This manual is related to the following products: