TROUBLESHOOTING (cont.)

Brew cycle will not start (cont.)

Water is not hot

Inconsistent beverage level in dis-
penser

PROBABLE CAUSE

REMEDY

7. Water strainer/flow control
(.222 GPM)(CWTA-APS, CWTFA-
APS, CWTA-TS, CWTFA-TS)

1. Tank Heater Switch

2. Limit Thermostat
CAUTION - Do not eliminate or
bypass limit thermostat. Use only
B.O.M. replacement part #29329.
1000 (CWTA-APS, CWTFA-APS,
CWTA-TS, CWTFA-TS)

3. Control Thermostat

4. Tank Heater

1. Strainer /flow control (.222
GPM) (CWTA-APS, CWTFA-APS,
CWTA-TS & CWTFA-TS

2. Syphon System

3. Lime Build-up
CAUTION - Tank and tank compo-
nents should be delimed regularly
depending on local water condi-
tions. Excessive mineral build-up
on stainless steel surfaces can ini-
tiate corrosive reactions resulting
in serious leaks.

(A) Direction of flow arrow must
be pointing towards brewer.

(B) Remove the strainer/flow con-
trol and check for obstructions.
Clear or replace.

Refer to

Service

- Tank Heater

Switch for testing procedures. See
page 20

Refer to

Service

- Limit Thermo-

stat for testing procedures. See
page 15

Refer to

Service

- Control Ther-

mostat for testing procedures. See
page 14

Refer to

Service

- Tank Heater for

testing procedures. See page 19

(A) Direction of flow arrow must
be pointing towards the brewer.

(B) Remove the strainer/flow con-
trol and check for obstruction.
Clear or replace.

The brewer must be level or slightly
lower in front to syphon properly.

Inspect the tank assembly for ex-
cessive lime deposits. Delime as
required.

10690.1 063000