TROUBLESHOOTING

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems

encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.

Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel.

All electronic components have 240 volt ac and low voltage dc potential on their terminals. Shorting of
terminals or the application of external voltages may result in board failure.

Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If an
intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a
terminal or crimp.

Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are
energized for more than ten minutes without a supply of water.

The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will help
to avoid twists and kinks in the tubing.

Make certain that all plumbing connections are sealed and electrical connections tight and isolated.

This brewer is heated at all times. Keep away from combustibles.

WARNING – • Exercise extreme caution when servicing electrical equipment.

• Unplug the brewer when servicing, except when electrical tests are specified.
• Follow recommended service procedures
• Replace all protective shields or safety notices

PROBLEM

Brew cycle will not start

PROBABLE CAUSE

1. No water (CWTA-APS, CWTFA-
APS, CWTA-TS & CWTFA-TS)

2. No power or incorrect voltage to
the brewer

3. ON/OFF Switch

4. Start Switch

5. Timer

6. Solenoid Valve

REMEDY

Water lines and valves to the brewer
must be open.

(A) Check the terminal block for
240 volts across the red and black
terminals.

(B) Check circuit breakers or fuses.

Refer to

Service

- ON/OFF Switch

for testing. See page 16

Refer to

Service

- Start Switch for

testing procedures. See page 18

Refer to

Service

- Timer for testing

procedures. See page 22 or 23

Refer to

Service

- Solenoid Valve

for testing procedures. See page
17