3

Operating Ambient

The minimum outdoor operating ambient in cooling mode is
55_F/12.78_C without low ambient cooling enabled, and the

maximum outdoor operating ambient in cooling mode is

125_F/51.67_C. On Evolution communicating systems only (for
both 286A and 288A), low ambient cooling is available to

0_F/--17.78_C.
The maximum outdoor operating ambient in heating mode is

66°F/18.89_C on all models.

Elevate Unit

CAUTION

!

UNIT OPERATION HAZARD
Failure to follow this caution may result in equipment

damage or improper operation.
Do not allow water and/or ice to build up in base pan.

Elevate unit per local climate and code requirements to provide

clearance above estimated snowfall level and ensure adequate
drainage of unit.

CAUTION

!

UNIT OPERATION HAZARD
Failure to follow this caution may result in equipment

damage or improper operation.
Locate the unit in such a way that it is stable in all

circumstances including adverse weather conditions.

In Long--Line Applications, Install Liquid--Line

Solenoid Valve (LSV)

For refrigerant piping arrangements with equivalent lengths greater
than 80 ft. (24.38 m) and/or when elevation difference between

indoor and outdoor unit is greater than ±20 ft. (±6.10 m), follow
all requirements of the Residential Piping and Longline Guideline.

If required by Long--Line Guideline, install LSV kit, part no.

KHALS0401LLS, specifically designed for PuronR refrigerant
heat pumps. LSV should be installed within 2 ft. (0.61 m) of

outdoor unit with flow arrow pointing toward outdoor unit. Follow
the Installation Instructions included with accessory kit.
IMPORTANT: Flow arrow must point toward outdoor unit.

Make Piping Connections

!

WARNING

PERSONAL INJURY AND UNIT DAMAGE

HAZARD
Failure to follow this warning could result in personal

injury or death.
Relieve pressure and recover all refrigerant before system

repair or final unit disposal. Use all service ports and open

all flow--control devices, including solenoid valves.

CAUTION

!

UNIT DAMAGE HAZARD
Failure to follow this caution may result in equipment

damage or improper operation.
Do not leave system open to atmosphere any longer than

minimum required for installation. POE oil in compressor is

extremely susceptible to moisture absorption. Always keep

ends of tubing sealed during installation.

CAUTION

!

UNIT DAMAGE HAZARD
Failure to follow this caution may result in equipment

damage or improper operation.
If ANY refrigerant tubing is buried, provide a 6 in. vertical

rise at service valve. Refrigerant tubing lengths up to 36 in.

(914.4 mm) may be buried without further special

consideration. Do not bury lines longer than 36 in. (914.4

mm).

Outdoor units may be connected to indoor section using accessory
tubing package or field--supplied refrigerant grade tubing of correct

size and condition. For tubing requirements beyond 80 ft. (24.38

m), substantial capacity and performance losses can occur.
Following the recommendations in the Residential Piping and

Longline Guideline will reduce these losses. Refer to Table 1 for
field tubing diameters. Refer to Table 2 for accessory requirements.

Outdoor Unit Connected to Factory--Approved Indoor

Unit

Outdoor unit contains correct system refrigerant charge for

operation with factory--approved, ARI--rated indoor unit with
highest sales volume when connected by 15 ft. (4.57 m) of

field--supplied or factory--accessory tubing, and factory--supplied

filter drier. Check refrigerant charge for maximum efficiency.

286A

/288A