Bryant Evolutiont Series s with Puronr Refrigerant 286A User Manual

Page 15

background image

15

RVS/Heat Stage 2

O/B W2

Heat Stage 1

W/W1

Compressor Low

Y1

Compressor High

Y/Y2

Fan

G

24VAC Hot Heating

Rh

24VAC Hot Cooling

Rc

Dry Contact 1

D1

Dry Contact 2

D2

24VAC Common

C

Humidify

HUM

Outdoor Air Temp

OAT

Remote Room Sensor

RRS

OAT/RRS Com

OAT/RRS

Outdoor Sensor *

Humidifier Solenoid

Valve *

Remote Room

Sensor *

O

Y1

W1

G

W2

C

Y2

R

W1

Y1

O

Y/Y2

R

C

DH

REMOVE J2
JUMPER FOR
HEAT STAGING

REMOVE J1 FOR
DEHUMIDIFY
MODES

2 STAGE

HEAT PUMP

THERMIDISTAT

FAN

COIL

A08055

Fig. 10 -- Edge Thermidistat Models T6--PRH--01 or T6--NRH--01)

Wiring with Two--Stage Heat Pump (non--communicating)

O

O/B W2

W2

W/W1

W/W1

W2

*

Heat/Cool Stage 1

Y1 / W2

Y1

Heat/Cool Stage 2

Y/Y2

Y/Y2

Y/Y2

Fan

G

G

24VAC Hot Heating

Rh

R

R

24VAC Hot Cooling

Rc

Dry Contact 1

D1

Dry Contact 2

D2

DHUM

24VAC Common

C

COM

C

Humidify

HUM

Outdoor Air Temp

OAT

Remote Room Sensor

RRS

OAT/RRS Com

SRTN

Outdoor Sensor *

Humidifier Solenoid

Valve *

Remote Room

Sensor *

Variable Speed

Furnace

Thermidistat

2-Stage

Heat Pump

* Indicates connection may not be required / available.

Heat Stage 3 (furnace)

RVS Cooling

A09337

Fig. 11 -- Thermidistat Model T6--PRH--01 or T6--NRH--01 with

Variable Speed Furnace and 2--Stage Heat Pump

(non--communicating)

D

C

B

A

User Interface

D

C

B

A

D

C

B

A

Communicating HP

OA

T

R

Y

O

W

C

HUM

C

Humidifier

24v

ac

Furnace or Fan Coil

A08091

Fig. 12 -- Evolution Furnace or Fan Coil Wiring with 286A OR 288A Communicating Two--Stage HP

286A

/288A