Table of burner and nozzle specifications – Hotpoint Ariston C 35S P6 R/HA User Manual
Page 18

18
GB
Table of burner and nozzle specifications
Table 1
Liquid Gas
Natural Gas
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
By Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nozzle
1/100
Flow*
l/h
Burner
Nominal Reduced
(mm)
(mm)
***
**
(mm)
(mm)
Triple
Crown (TC)
130
3.25
1.50
63
91
236
232
133
309
150
309
Semi Fast
(Medium)(S)
75
1.90
0.4
30
70
138
136
104
181
118
181
Auxiliary
(Small)(A)
51
1.00
0.4
30
52
73
71
76
95
80
95
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
13
6,5
18
*
At 15°C 1013 mbar-dry gas
***
Butane P.C.S. = 49,47 MJ/Kg
**
Propane P.C.S. = 50,37 MJ/Kg
Natural P.C.S. = 37,78 MJ/m³
S S
TC
A
C35SP6R /HA
TABLE OF CHARACTERISTSICS
Dimensions
Oven HxWxD
34xx38x41
Volume
53 l
Useful
measurements
relating to the oven
compartment
width 42 cm
depth 44 cm
height 17 cm
Burners
may be adapted for use with any type of
gas shown on the data plate, which is
located inside the flap or, after the oven
compartment has been opened, on the
left-hand wall inside the oven.
Voltage and
frequency
see data plate
ENERGY LABEL
Directive 2002/40/EC on the label of
electric ovens.
Standard EN 50304
Energy consumption for Natural
convection – heating mode:
=
Traditional mode;
Declared energy consumption for
Forced convection Class – heating
mode:
K Baking mode.
This appliance conforms to the following
European Economic Community
directives: 73/23/EEC dated 19/02/73
(Low Voltage) and subsequent
amendments - 89/336/EEC dated
03/05/89 (Electromagnetic
Compatibility) and subsequent
amendments - 93/68/EEC dated
22/07/93 and subsequent amendments.
2002/96/EEC