TROUBLESHOOTING SUGGESTIONS

14

CAUTION:

SHOCK HAZARD

Opening access panels may expose uninsulated electrical components.
Disconnect dispenser from electrical power before removing any panel. Do not attempt to repair or
replace components without first unplugging the power cord. Use caution when adjusting water flow
rates or testing voltages with power applied to the unit. Electrical shock can cause injury or death.

PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

DISPENSER WILL NOT WORK

Line cord not plugged into outlet.

Connect line cord to outlet

Outlet has no power.

Check / reset circuit breaker

Power switch not

ON

Turn power switch

ON

Wiring damaged or loose connection

Check wiring for condition and tightness

Power switch damaged

Replace power switch

DISPENSER DOES NOT DISPENSE
WATER

Water supply not turned on

Turn water supply valve

ON

Water tank not filled

See installation procedure

Wire not connected

Check wire connections

Flow control on valve closed

Open flow control, see richer / leaner
procedure

Water inlet valve plugged

Disassemble and clean inlet valve.

Water inlet valve defective

Replace water inlet valve

DISPENSER WILL NOT FILL

Power switch not

ON

Turn power switch

ON

Water supply not

ON

Open water supply valve

Stuck or frozen inlet valve

Remove valve coil, gently lift off valve
dome and diaphragm, clean diaphragm

Defective water inlet valve

Replace inlet valve

Defective control board

Replace control board

Sensor probe bent and touching tank

Straighten bent probe

DISPENSER OVERFLOWS

Inlet valve does not fully close

Remove valve coil, gently lift off valve
dome and diaphragm, clean diaphragm

Defective inlet valve

Replace inlet valve.

Wire off sensor probe connection

Reconnect wire

Defective sensor probe

Replace sensor and/or control board

Sensor probes not positioned

Check vertical position of sensor probes

DISPENSER FLOW ERRATIC

Diverter not in Blender spout

Insert Diverter in spout

Blender spout partially clogged

Clean spout

Power switch not

ON

Turn power switch

ON

Keypad ribbon cable loose

Check ribbon cable connection

Loose or disconnected wires

Check for loose wires

Keypad switch defective

Replace keypad

DISPENSER WILL NOT START WHEN
BUTTON(S) ARE PRESSED