Calculated Industries 5070-B User Guide User Manual
Page 24

U
ser
'
s
G
Uide
— 23
3. Enter as VA:
Va 43,370.
4. Enter Volts:
VolT 240.
5. Solve for Amps:
aMPs 180.70833
finding amps from Kilowatts
What is the Amperage for a 75 kW load connected in a 120/208 Volt,
3Ø circuit?
KeysTRoKe
DIsPlay
0.
1. Set to 3-Phase:
(3Ш)
3Ш
Ph
2. Enter kilowatts:
KW 75.
3. Enter Volts:
VolT 208.
4. Solve for Amps:
aMPs 208.17918
finding Volt-amps
What is the VA rating for a 120 Volt, 22 Amp, 1Ø circuit? What is the
kVA rating?
KeysTRoKe
DIsPlay
0.
1. Set to 1-Phase:
(1Ш)
1 Ш
1 Ph
KeysTRoKe
DIsPlay
(cont’d)
See also other documents in the category Calculated Industries Calculators, organizers:
- 4215 (64 pages)
- 4225-B (52 pages)
- 4225-C (52 pages)
- 44060 (134 pages)
- 4050 Metric Edition (44 pages)
- 4050 (52 pages)
- 4050 v3.1 (52 pages)
- 4050-F (52 pages)
- 4054 (52 pages)
- 4045-B (54 pages)
- 4045 (26 pages)
- 4067 Pocket Reference Guide (52 pages)
- 4067 User Guide (23 pages)
- 4065 v3.0 (108 pages)
- 4065 v3.1 Pocket Reference Guide Construction Master Pro (39 pages)
- 4065 v3.1 Pocket Reference Guide Advanced Consnruction-Math (40 pages)
- 4065 v3.1 User Guide (110 pages)
- 8030 (44 pages)
- 5025 (48 pages)
- 5065 (71 pages)
- 5070-A Pocket Reference Guide (45 pages)
- 5070-B Pocket Reference Guide (46 pages)
- 5070-A User Guide (66 pages)
- 4315 (56 pages)
- 4320 (51 pages)
- 4325 (53 pages)
- 4090 (123 pages)
- 4019 (40 pages)
- 4018 (38 pages)
- 4015 (84 pages)
- 4020 (39 pages)
- 4095-A Pocket Reference Guide (36 pages)
- 4095-B Pocket Reference Guide (38 pages)
- 4095-C Pocket Reference Guide (23 pages)
- 4095-A User Guide (50 pages)
- 4095-B User Guide (68 pages)
- 4095-C User Guide (65 pages)
- 4094 Pocket Reference Guide (38 pages)
- 4094 User Guide (44 pages)
- 8545 (48 pages)
- 4400 (50 pages)
- 8015 (64 pages)
- 8020 (52 pages)
- 8025 (47 pages)