4. Bring 1/4” water supply line from source (See page 6) to cut
opening as shown in
opening
opening
Figure 2. (page 9). Bring water line through
grommet in rough-in-box (See Supply Detail). Carefully slide
rough-In-box as shown into cut opening while gently pulling
cut opening
cut opening
water supply line through grommet hole in rough-in-box pulling
through excess (approx 18”). Secure rough-in-box to wall stud
with sheet rock screws. PURGE WATER LINE by running water
through line to clean any possible debris. Cut water line to length
(approx 3”) inside rough-in-box and attach male quick connector.
(See Male Connector Detail) and Figure 4.
IMPORTANT:
Water line to brewer must be fl ushed and a fi lter installed.
Should debris clog brewer system ALL WARRANTIES VOID.
10
11
BREWER INSTALLATION
BREWER INSTALLATION
10
10
10
11
11
11
5. After sheet rock screws are in place, gently bend appropriate
tabs (long or short depending on wall thickness such as tile
or granite) as shown on all other areas to fi nish securing
rough-in box to wall. Use pliers (if needed) to bend/crimp
tabs fi rmly to wall. Gently slide excess water line back through
grommet into wall cavity leaving top of connector a maximum of
3” above bottom of rough-in box. See Figure 5. and Figure 6.
Installation of Brewer
6. Quick connector is valved at rough-in-box so water can be
turned on prior to connection to coffee maker. Place unit on
a towel or cardboard to protect counter surface. Place
BREW EXPRESS™ directly in front of rough-in box. Use quick
connector to connect water supply line from BREW EXPRESS™
to water supply line from rough-in-box (See Quick Connect Detail).
Snap connectors together fi rmly. Turn on water, check for leaks prior
to fi nal installation of BREW EXPRESS™. If leaking, turn off water,
tighten connections or reinstall quick connector. Turn water on
and check again. See Figure 7.
7. Gently slide the BREW EXPRESS™ into the rough-in-box.
Be careful not to damage water supply lines. A fi rm fi t will
connect power from rough-in-box to the BREW EXPRESS™.
Use four mounting screws to secure BREW EXPRESS™
inside rough-in-box. Be careful not to damage counter top.
NOTE: Refer to OPERATION GUIDE for further instructions
before using BREW EXPRESS™.
3" max
Figure 5
Quick Connect Detail
Figure 6
Figure 7
Figure 4
Supply Detail
Wiring Detail
Male Connector Detail